Introduction: Normoglycaemia in people with diabetes results in improved outcome. Continuous glucose monitoring provides detailed diagnostic information used to optimise therapy with the goal of achieving normoglycaemia. The objective of this study was to review the published literature evaluating the single device available for blinded, professional clinical use of continuous glucose monitoring; in particular all randomised controlled trials (RCTs) and relevant observational studies.

Methods: Published studies (to 31 March 2009) using the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS System Gold, Medtronic MiniMed, Inc., Northridge, CA) were identified using appropriate search terms in a series of clinical databases including: Medline, Pubmed, Google Scholar and Scientific Web of Knowledge. Other measures were also taken such as reviewing the reference lists.

Findings: In addition to an extensive range of non-randomised studies using the device, seven randomised controlled trials were identified, of which five were in children. Although HbA1c was explicitly stated as the primary endpoint in four studies, the studies were only adequately powered to detect large, between-group minimum differences (range 0.5 to 1.0% HbA1c). Only two studies included subjects with type 2 diabetes. Other endpoints included the frequency of hypoglycaemia and hyperglycaemia. Within-group HbA1c decreases were observed in all but one study. The crude, weighted mean improvement in HbA1c across the studies using the device was 0.6% (range 0% to 0.8%). When compared to a control measure the weighted, mean marginal benefit in HbA1c was 0.2%. No studies recorded how the information was utilised to modify treatment, such as changes in dose titration or treatment regimen.

Conclusions: Devices such as the professional CGMS provide detailed diagnostic information. However, any consequent changes in care and outcome can only result from the appropriate application of this information. Although there was a notable improvement in glucose control (HbA1c), existing studies were largely underpowered and did not capture the resulting treatment changes that could lead to improved outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1185/03007990903094452DOI Listing

Publication Analysis

Top Keywords

continuous glucose
16
glucose monitoring
16
people diabetes
8
improved outcome
8
detailed diagnostic
8
randomised controlled
8
controlled trials
8
studies
8
medtronic minimed
8
studies device
8

Similar Publications

Objectives: This study aimed to evaluate the effects of pre-conditioning exercise on body lipid metabolism, leptin secretion, and the downstream pathways at the early stage of type 2 diabetes mellitus (T2DM).

Materials And Methods: The T2DM model was established using an 8-week high-sugar, high-fat diet combined. The T2DM model was established using an 8-week high-sugar, high-fat diet combined with streptozocin (STZ) injection.

View Article and Find Full Text PDF

Background: This study aimed to compare the economic value of intermittent-scanning continuous glucose monitoring (isCGM) with self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes (T1D).

Methods: Participants were placed on either an isCGM or SMBG arm for 84 days, in a randomized, crossover setup with a 28-day washout period. Clinically relevant hypoglycemia (<54 mg/dL) and severe hypoglycemia (SH) risks were calculated by analyzing the data from isCGM.

View Article and Find Full Text PDF

A 58-year-old woman with a body mass index of 26.4 kg/m was referred because of high glycated hemoglobin (HbA1c) at a medical checkup. Her anti-glutamic acid decarboxylase antibody (GADA) titer was positive (16.

View Article and Find Full Text PDF

Patients with Turner Syndrome (TS) and those exposed to high concentrations of glucocorticoids have a number of characteristics in common, including an increased risk of cardiovascular disease. Pediatric TS patients underwent studies of salivary cortisol (SC) and cortisone (SCn), body composition, continuous glucose monitoring, vascular function, and ambulatory blood pressure (BP). Biochemical indicators of cardiovascular risk were also measured.

View Article and Find Full Text PDF

Aims: This study assessed real-world glycaemic outcomes associated with the use of Dexcom ONE in adults with suboptimally controlled diabetes.

Methods: In this single-site prospective study, adults with type 1 (T1D) or type 2 diabetes (T2D) taking two or more insulin injections per day initiated Dexcom ONE CGM use and attended follow-up data collection visits after 3 and 6 months. During the study, participants received usual diabetes care.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!