A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression. | LitMetric

Unlabelled: The workings of the auditory pathway of patients with tinnitus and normal hearing can be associated with an auditory efferent pathway dysfunction at the level of the superior olivary complex. Otoacoustic emission suppression with contralateral noise can represent an alternative to its evaluation.

Aim: to investigate Transient Otoacoustic Emission suppression in normal hearing adults with and without tinnitus and to compare the two groups.

Study Design: cross-sectional contemporary cohort.

Materials And Methods: we assessed 40 female individuals between 18 and 59 years of age, 20 without tinnitus and 20 with it. We studied the TOAE suppression with a contralateral white noise at 50 dBSPL.

Results: TOAE amplitude was lower in the group with tinnitus. There was no difference between the groups with and without tinnitus in terms of TOAE suppression, except in the frequency of 1000 Hz in the left ear in the tinnitus group.

Conclusion: the afferent system assessment may contribute to the topographic diagnosis of tinnitus; however, we still need further studies to establish the proper methodology and normative values to carry out these tests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9445889PMC
http://dx.doi.org/10.1016/S1808-8694(15)30660-1DOI Listing

Publication Analysis

Top Keywords

normal hearing
12
tinnitus
8
tinnitus normal
8
transient otoacoustic
8
otoacoustic emission
8
emission suppression
8
suppression contralateral
8
toae suppression
8
suppression
5
hearing study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!