The noise spectrum influence on Noise-Induced Hearing Loss prevalence in workers.

Braz J Otorhinolaryngol

Laboratório de Saúde do Trabalhador, Departamento de Saúde Coletiva, Faculdade de Saúde, Universidade de Brasília.

Published: February 2010

Unlabelled: Noise Induced Hearing Loss (NIHL) is an insidious and cumulative disease that worsens over the years with work-related noise exposure.

Aim: To evaluate the noise spectrum influence on NIHL prevalence in workers.

Materials And Methods: This a cross-sectional historical cohort carried out in steel mills, lumber mills and marble shops, with noise levels above 85dB, in which we evaluated the auditory thresholds for frequencies from 250Hz to 8,000Hz. To evaluate the work environment, we observed the entire setting, aiming at checking sound intensities in an eighth frequency filter.

Results: We carried out 192 hearing threshold evaluations after an occupational anamnesis. Concerning NIHL, we noticed that 49% of the audiometry results presented hearing deterioration in the acute frequencies. We studied the mean values and standard deviations for frequencies over 3,000Hz, in all workers, and we observed that the highest average values were in the frequency of 6,000Hz. We did not notice any association among frequency bands carrying intense noise levels and the hearing damage frequency.

Conclusion: Noise intensity seems to be the main risk factor for loss hearing, regardless of frequency range.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9445875PMC
http://dx.doi.org/10.1016/s1808-8694(15)30646-7DOI Listing

Publication Analysis

Top Keywords

noise spectrum
8
spectrum influence
8
hearing loss
8
noise levels
8
noise
7
hearing
6
influence noise-induced
4
noise-induced hearing
4
loss prevalence
4
prevalence workers
4

Similar Publications

Spectral Content Effects Study in Non-Contact Resonance Ultrasound Spectroscopy.

Sensors (Basel)

January 2025

Department of Electronics Engineering, Kaunas University of Technology, 51368 Kaunas, Lithuania.

The application of spread-spectrum signals (arbitrary pulse width and position (APWP) sequences) in air-coupled resonant ultrasound spectroscopy is studied. It was hypothesized that spread-spectrum signal optimization should be based on te signal to noise ratio (SNR). Six APWP signal optimization criteria were proposed for this purpose.

View Article and Find Full Text PDF

Purpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.

View Article and Find Full Text PDF

Objectives: The objectives of this study were to evaluate the relationships between auditory processing, speech discrimination, and listening and communication abilities in children diagnosed with auditory neuropathy spectrum disorder (ANSD) compared to those with normal hearing.

Methods: This was a case-control study involving seventeen participants with a diagnosis of ANSD who used spoken language as their primary mode of communication and wore hearing aids or were unaided and 21 normally hearing controls. All underwent a battery of behavioural measures of hearing, speech perception and auditory processing skills.

View Article and Find Full Text PDF

Convergent-Diffusion Denoising Model for multi-scenario CT Image Reconstruction.

Comput Med Imaging Graph

January 2025

The Department of Computer and Data Science, Case Western Reserve University, Cleveland, OH, USA; The Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.

A generic and versatile CT Image Reconstruction (CTIR) scheme can efficiently mitigate imaging noise resulting from inherent physical limitations, substantially bolstering the dependability of CT imaging diagnostics across a wider spectrum of patient cases. Current CTIR techniques often concentrate on distinct areas such as Low-Dose CT denoising (LDCTD), Sparse-View CT reconstruction (SVCTR), and Metal Artifact Reduction (MAR). Nevertheless, due to the intricate nature of multi-scenario CTIR, these techniques frequently narrow their focus to specific tasks, resulting in limited generalization capabilities for diverse scenarios.

View Article and Find Full Text PDF

Optical density measurement has been used for decades to determine the microorganism concentration and more rarely for mammalian cells. Although this measurement can be carried out at any wavelength, studies report a limited number of measurement wavelengths, mainly around 600 nm, and no consensus seems to be emerging to propose an objective method for determining the optimum measurement wavelength for each microorganism. In this article, we propose a method for analyzing the absorbance spectra of ESKAPEE bacteria and determining the optimum measurement wavelength for each of them.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!