Used for decades for biological warfare, Bacillus anthracis (category A agent) has proven to be highly stable and lethal. Quantitative risk assessment modeling requires descriptive statistics of the limit of detection to assist in defining the exposure. Furthermore, the sensitivities of various detection methods in environmental matrices are vital information for first responders. A literature review of peer-reviewed journal articles related to methods for detection of B. anthracis was undertaken. Articles focused on the development or evaluation of various detection approaches, such as PCR, real-time PCR, immunoassay, etc. Real-time PCR and PCR were the most sensitive methods for the detection of B. anthracis, with median instrument limits of detection of 430 and 440 cells/ml, respectively. There were very few peer-reviewed articles on the detection methods for B. anthracis in the environment. The most sensitive limits of detection for the environmental samples were 0.1 CFU/g for soil using PCR-enzyme-linked immunosorbent assay (ELISA), 17 CFU/liter for air using an ELISA-biochip system, 1 CFU/liter for water using cultivation, and 1 CFU/cm(2) for stainless steel fomites using cultivation. An exponential dose-response model for the inhalation of B. anthracis estimates of risk at concentrations equal to the environmental limit of detection determined the probability of death if untreated to be as high as 0.520. Though more data on the environmental limit of detection would improve the assumptions made for the risk assessment, this study's quantification of the risk posed by current limitations in the knowledge of detection methods should be considered when employing those methods in environmental monitoring and cleanup strategies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2753060PMC
http://dx.doi.org/10.1128/AEM.00288-09DOI Listing

Publication Analysis

Top Keywords

detection methods
16
detection
12
limits detection
12
limit detection
12
bacillus anthracis
8
risk assessment
8
methods environmental
8
methods detection
8
detection anthracis
8
real-time pcr
8

Similar Publications

Acoustic emission information can describe the damage degree of rock samples in the process of failure. However, as a discrete non-stationary signal, acoustic emission information is difficult to be effectively processed by conventional methods, while wavelet analysis is an effective method for non-stationary signal processing. Therefore, acoustic emission signal is deeply studied by using wavelet analysis method.

View Article and Find Full Text PDF

Surface-enhanced Raman scattering (SERS) technology has attracted more and more attention due to its high sensitivity, low water interference, and quick measurement. Constructing high-performance SERS substrates with high sensitivity, uniformity and reproducibility is of great importance to put the SERS technology into practical application. In this paper, we report a simple fabrication process to construct dense silver-coated PMMA nanoparticles-on-a-mirror SRES substrates.

View Article and Find Full Text PDF

Design of integrated radar and communication system based on solvable chaotic signal.

Sci Rep

December 2024

Shaanxi Key Laboratory of Complex System Control and Intelligent Informantion Processing, Xi'an University of Technology, Xi'an 710048, China.

In the integrated radar and communication system (IRCS), the design of signal that can simultaneously satisfy the radar detection and communication transmission is very important and difficult. Recently, some new properties of a class of solvable chaotic system have been studied for wireless applications, such as low bit error rate (BER) wireless communications and low cost target detection. In this paper, a novel IRCS based on the chaotic signal is proposed, and the performance of proposed scheme is analyzed.

View Article and Find Full Text PDF

Using Fourier Transform Infrared spectroscopy (FTIR), it is possible to show chemical composition of materials and / or profile chemical changes occurring in tissues, cells, and body fluids during onset and progression of diseases. For diagnostic application, the use of blood would be the most appropriate in biospectroscopy studies since, (i) it is easily accessible and, (ii) enables frequent analyses of biochemical changes occurring in pathological states. At present, different studies have investigated potential of serum, plasma and sputum being alternative biofluids for lung cancer detection using FTIR.

View Article and Find Full Text PDF

Nursing activity recognition has immense importance in the development of smart healthcare management and is an extremely challenging area of research in human activity recognition. The main reasons are an extreme class-imbalance problem and intra-class variability depending on both the subject and the recipient. In this paper, we apply a unique two-step feature extraction, coupled with an intermediate feature 'Angle' and a new feature called mean min max sum to render the features robust against intra-class variation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!