A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biocompatibility of new drug-eluting biodegradable urethral stent materials. | LitMetric

Objectives: To investigate the effects of biodegradable stent material (poly-96L/4D-lactic acid [PLA]) on the production of cytokines and other inflammatory mediators in vitro and the biocompatibility of new drug-eluting biodegradable urethral stent materials in vivo. Indomethacin, dexamethasone, and simvastatin were used in the materials.

Methods: The effects of the biodegradable stent material on cytokines and other inflammatory mediators were measured using the Human Cytokine Antibody Array and enzyme-linked immunosorbent assay in THP-1 cells, with bacterial lipopolysaccharide as a positive control. To assess the biocompatibility of the stent materials, we used muscle implantation. Biodegradable stent materials without drug-eluting properties and silicone and latex were used as controls. The measurements were done at 3 weeks and 3 months.

Results: The PLA stent material induced production of inflammatory mediators, especially interleukin-8, tumor necrosis factor-alpha, and transforming growth factor-beta, in vitro. The increase in the production of these mediators with the PLA stent material was smaller than in the cells treated with lipopolysaccharide. In vivo, the effects of the biodegradable materials did not differ at 3 weeks, although, at 3 months, dexamethasone had induced more tissue reactions than had the other materials. At 3 months, fibrosis and chronic inflammatory changes were decreased in the biodegradable material groups compared with the positive control.

Conclusions: PLA stent material increased the production of cytokines and other inflammatory mediators less than did positive controls in vitro. The in vivo biocompatibility of the drug-eluting biodegradable materials was better than that of the positive controls. Drug-eluting biodegradable urethral stents could potentially offer a new treatment modality in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2009.03.016DOI Listing

Publication Analysis

Top Keywords

stent material
20
drug-eluting biodegradable
16
stent materials
16
inflammatory mediators
16
biocompatibility drug-eluting
12
biodegradable urethral
12
effects biodegradable
12
biodegradable stent
12
cytokines inflammatory
12
pla stent
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!