A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-resolution diffusion tensor imaging of the human pons with a reduced field-of-view, multishot, variable-density, spiral acquisition at 3 T. | LitMetric

Diffusion tensor imaging of localized anatomic regions, such as brainstem, cervical spinal cord, and optic nerve, is challenging because of the existence of significant susceptibility differences, severe physiologic motion in the surrounding tissues, and the need for high spatial resolution to resolve the underlying complex neuroarchitecture. The aim of the methodology presented here is to achieve high-resolution diffusion tensor imaging in localized regions of the central nervous system that is motion insensitive and immune to susceptibility while acquiring a set of two-dimensional images with more than six diffusion encoding directions within a reasonable total scan time. We accomplish this aim by implementing self-navigated, multishot, variable-density, spiral encoding with outer volume suppression. We establish scan protocols for achieving equal signal-to-noise ratio at 1.2 mm and 0.8 mm in-plane resolution for reduced field-of-view diffusion tensor imaging of the brainstem. In vivo application of the technique on the human pons of three subjects shows a clear delineation of the multiple local neural tracts. By comparing scans acquired with varying in-plane resolution but with constant signal-to-noise ratio, we demonstrate that increasing the resolution and reducing the partial volume effect result in higher fractional anisotropy values for the corticospinal tracts.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.22105DOI Listing

Publication Analysis

Top Keywords

diffusion tensor
16
tensor imaging
16
high-resolution diffusion
8
human pons
8
reduced field-of-view
8
multishot variable-density
8
variable-density spiral
8
imaging localized
8
signal-to-noise ratio
8
in-plane resolution
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!