One-step extraction and derivatization liquid-phase microextraction for the determination of chlorophenols by gas chromatography-mass spectrometry.

J Chromatogr A

State Key Laboratory of Biocontrol/MOE Key Laboratory of Aquatic Product Safety, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, China.

Published: August 2009

AI Article Synopsis

Article Abstract

A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography-mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one step. High sensitivity of 18 CPs derivatives could be achieved after optimization of several parameters such as extraction solvent, percentage of derivatization reagent, extraction time, pH, and ionic strength. The results from the optimal method showed that calibration ranging from 0.5 to 500microgL(-1) could be achieved with the RSDs between 1.75% and 9.39%, and the limits of detection (LOD) are ranging from 0.01 to 0.12microgL(-1) for the CPs. Moreover, the proposed LPME method was compared with solid-phase microextraction (SPME) coupled with on-fiber derivatization technique. The results suggested that using both methods are quite agreeable. Furthermore, the recoveries of LPME evaluated by spiked environmental samples ranged from 87.9% (3,5-DCP) to 114.7% (2,3,5,6-TeCP), and environmental water samples collected from the Pearl River were analyzed with the optimized LPME method, the concentrations of 18 CPs ranged from 0.0237microgL(-1) (3,5-DCP) to 0.3623microgL(-1) (2,3,6-TCP).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2009.07.011DOI Listing

Publication Analysis

Top Keywords

derivatization liquid-phase
8
liquid-phase microextraction
8
determination chlorophenols
8
gas chromatography-mass
8
chromatography-mass spectrometry
8
derivatization reagent
8
extraction solvent
8
lpme method
8
derivatization
6
one-step extraction
4

Similar Publications

A Protocol for GC-MS Profiling of Chiral Secondary Amino Acids.

Methods Mol Biol

January 2025

Laboratory of Analytical Biochemistry & Metabolomics, Biology Centre, Czech Academy of Sciences, České Budějovice, Czech Republic.

A simple analytical workflow is described for gas chromatographic-mass spectrometric (GC-MS)-based chiral profiling of secondary amino acids (AAs) in biological matrices. The sample preparation is carried out directly in aqueous biological sample extracts and involves in situ heptafluorobutyl chloroformate (HFBCF) derivatization-liquid-liquid microextraction of nonpolar products into hexane phase followed by subsequent formation of the corresponding methylamides from the HFB esters by direct treatment with methylamine reagent solution. The (O, N) HFB-butoxycarbonyl-methylamide AA products (HFBOC-MA) are separated on a Chirasil-L-Val capillary column and quantitatively measured by GC-MS operated in selected ion monitoring (SIM) mode.

View Article and Find Full Text PDF

Application of 1-octanol in the extraction and GC-FID analysis of volatile organic compounds produced in biogas and biohydrogen processes.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

São Paulo State University (UNESP), Institute of Chemistry, Center for Monitoring and Research of the Quality of Fuels, Biofuels, Crude Oil, and Derivatives (CEMPEQC), Rua Professor Francisco Degni, 55, Araraquara, SP 14800-900, Brazil; Federal University of Paraná (UFPR), Palotina campus, Rua Pioneiro, 2153, Palotina, PR 85950-000, Brazil. Electronic address:

Article Synopsis
  • * Researchers used gas chromatography and a specialized extraction method to analyze 12 specific compounds, including common alcohols and acids, validating their findings with statistical methods for accuracy.
  • * Findings revealed high levels of methanol and highlighted acetic acid and ethanol as the most abundant compounds; the method used is environmentally friendly, requiring fewer steps and no dispersing solvent.
View Article and Find Full Text PDF

Automated liquid-liquid deep eutectic solvents based microextraction procedure for determination of acrylamide in foodstuffs by high-performance liquid chromatography with ultraviolet detection.

J Food Sci Technol

December 2024

Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab, St. Petersburg, Russia 199034.

Unlabelled: For the rapid and efficient determination of acrylamide in food products by HPLC-UV, an environmentally friendly analytical approach has been developed, including liquid-phase extraction and subsequent liquid-liquid microextraction using a deep eutectic solvent. To automate the procedure, the flow-through "lab in a syringe" method was used. Acrylamide is considered a potential endocrine disrupting chemical and its main source is fried foods, which are widely consumed by both children and adults.

View Article and Find Full Text PDF

Acrylamide, a probable human carcinogen present in heat-processed foods and environmental contaminants, requires sample extraction and preconcentration before chromatographic analysis. The method developed in this study employed derivatization with xanthydrol and dispersive liquid-liquid microextraction utilizing low-density anisole. Durian or potato chips were combined with deionized water, defatted with hexane, and subjected to precipitation of soluble carbohydrates and proteins using clarification reagents.

View Article and Find Full Text PDF

Natural deep eutectic solvent for the simultaneous derivatization and microextraction of isoniazid from human plasma.

Anal Chim Acta

September 2024

Department of Analytical Chemistry, Institute of Chemistry, Saint Petersburg State University, SPbSU, 7/9 Universitetskaya nab., St. Petersburg, 199034, Russia.

Background: Personalized medicine is a rapidly revolving field that offers new opportunities for tailoring disease treatment to individual patients. The main idea behind this approach is to carefully select safe and effective medications and treatment plant based on each patient's unique pharmacokinetic profile. Isoniazid is a first-line anti-tuberculosis drug that has interindividual variability in its metabolic processing, leading to significant differences in plasma concentrations among patients receiving equivalent doses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!