Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The aim of our study is to confirm the reliability of optic nerve ultrasound as a method to detect intracranial hypertension in patients with spontaneous intracranial hemorrhage, to assess the reproducibility of the measurement of the optic nerve sheath diameter (ONSD), and to verify that ONSD changes concurrently with intracranial pressure (ICP) variations.
Methods: Sixty-three adult patients with subarachnoid hemorrhage (n = 34) or primary intracerebral hemorrhage (n = 29) requiring sedation and invasive ICP monitoring were enrolled in a 10-bed multivalent ICU. ONSD was measured 3 mm behind the globe through a 7.5-MHz ultrasound probe. Mean binocular ONSD was used for statistical analysis. ICP values were registered simultaneously to ultrasonography. Twenty-eight ONSDs were measured consecutively by two different observers, and interobserver differences were calculated. Twelve coupled measurements were taken before and within 1 min after cerebrospinal fluid (CSF) drainage to control elevated ICP.
Results: Ninety-four ONSD measurements were analyzed. 5.2 mm proved to be the optimal ONSD cut-off point to predict raised ICP (>20 mmHg) with 93.1% sensitivity (95% CI: 77.2-99%) and 73.85% specificity (95% CI: 61.5-84%). ONSD-ICP correlation coefficient was 0.7042 (95% CI for r = 0.5850-0.7936). The median interobserver ONSD difference was 0.25 mm. CSF drainage to control elevated ICP caused a rapid and significant reduction of ONSD (from 5.89 ± 0.61 to 5 ± 0.33 mm, P < 0.01).
Conclusion: Our investigation confirms the reliability of optic nerve ultrasound as a non-invasive method to detect elevated ICP in intracranial hemorrhage patients. ONSD measurements proved to have a good reproducibility. ONSD changes almost concurrently with CSF pressure variations.