Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The aim of the present study was to evaluate the bioequivalence of two oral clopidogrel (CAS 113665-84-2) formulations.
Method: The study was conducted as a monocentric, open, randomized, single-dose, two-period crossover trial in 48 healthy volunteers with a duration of hospitalization of approximately 24 h after dosing on day 1 and with a real wash-out period of 7 days. Blood samples were collected for 24 h post dosing in each period. The plasma was separated and the concentrations of clopidogrel were determined by a LC-MS/MS method. AUC(0-tlast), Cmax, tmax, AUC(0-inf), MRT and t1/2 were calculated for both formulations.
Results: The arithmetic means of AUC(0-tlast) and Cmax were 3,656.01 pg x h/ml and 1970.22 pg/ml for the test formulation and 3771.51 pg x h/ml and 1756.52 pg/ml, respectively, for the reference formulation. The mean tmax was 1.16 h for the test and 1.13 h for the reference formulation. The point estimators of the ratios of the test and reference formulations for AUC(0-tlast) and Cmax were 1.042 and 1.115, respectively. Furthermore, the 90% confidence intervals calculated by means of ANOVA-log for the first primary endpoint of the trial, the intra-individual ratio (T/R) of AUC(0-tlast) of clopidogrel was between 0.932 and 1.165. The 90% confidence interval calculated by means of ANOVA-log for Cmax of clopidogrel was between 0.973 and 1.277. The 90% confidence intervals for both parameters were within the predefined acceptance ranges (0.80-1.25 for AUC(0-tlast) and 0.75-1.33 for Cmax). The intraindividual coefficients of variation determined by means of ANOVA-log were 33.51% for AUC(0-tlast) and 41.29% for Cmax.
Conclusion: While both products were bioequivalent in terms of the rate and extent of absorption, the present study also confirmed a high variability for clopidogrel suggesting high volunteer numbers in bioequivalence trials.