Previous studies showed strong correlations between low fingertip temperature rebound measured by digital thermal monitoring (DTM) during a 5 min arm-cuff induced reactive hyperemia and both the Framingham Risk Score (FRS), and coronary artery calcification (CAC) in asymptomatic populations. This study evaluates the correlation between DTM and coronary artery disease (CAD) measured by CT angiography (CTA) in symptomatic patients. It also investigates the correlation between CTA and a new index of neurovascular reactivity measured by DTM. 129 patients, age 63 +/- 9 years, 68% male, underwent DTM, CAC and CTA. Adjusted DTM indices in the occluded arm were calculated: temperature rebound: aTR and area under the temperature curve aTMP-AUC. DTM neurovascular reactivity (NVR) index was measured based on increased fingertip temperature in the non-occluded arm. Obstructive CAD was defined as >or=50% luminal stenosis, and normal as no stenosis and CAC = 0. Baseline fingertip temperature was not different across the groups. However, all DTM indices of vascular and neurovascular reactivity significantly decreased from normal to non-obstructive to obstructive CAD [(aTR 1.77 +/- 1.18 to 1.24 +/- 1.14 to 0.94 +/- 0.92) (P = 0.009), (aTMP-AUC: 355.6 +/- 242.4 to 277.4 +/- 182.4 to 184.4 +/- 171.2) (P = 0.001), (NVR: 161.5 +/- 147.4 to 77.6 +/- 88.2 to 48.8 +/- 63.8) (P = 0.015)]. After adjusting for risk factors, the odds ratio for obstructive CAD compared to normal in the lowest versus two upper tertiles of FRS, aTR, aTMP-AUC, and NVR were 2.41 (1.02-5.93), P = 0.05, 8.67 (2.6-9.4), P = 0.001, 11.62 (5.1-28.7), P = 0.001, and 3.58 (1.09-11.69), P = 0.01, respectively. DTM indices and FRS combined resulted in a ROC curve area of 0.88 for the prediction of obstructive CAD. In patients suspected of CAD, low fingertip temperature rebound measured by DTM significantly predicted CTA-diagnosed obstructive disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2729419 | PMC |
http://dx.doi.org/10.1007/s10554-009-9476-8 | DOI Listing |
J Hematol
December 2024
Department of Clinical Health Sciences, Doisy College of Health Sciences, Saint Louis University, St. Louis, MO 63104, USA.
Background: Anemia is a global health issue that affects over 1 billion people and contributes to maternal mortality and birth defects. Low-resource, tropical areas face a dual challenge: high prevalence of anemia and inability to access affordable testing methods. The falling drop hemoglobin method has been developed by our lab to quantify hemoglobin concentration and assess anemia by timing the descent of venous blood in a column of copper sulfate solution, without using electricity or batteries.
View Article and Find Full Text PDFJ Biomech Eng
February 2025
Department of Electrical and Mechanical Engineering, Graduate School of Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan; Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan; Department of Nanopharmaceutical Sciences, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan.
Capillary refill time (CRT) is a widely used noninvasive measure of cardiovascular health. Despite its widespread diagnostic utility, it has several limitations, particularly its low sensitivity for certain conditions, because factors such as the contraction and relaxation of distal blood vessels can influence CRT readings. This study was performed to explore the relationships between CRT and distal blood flow.
View Article and Find Full Text PDFActa Psychol (Amst)
November 2024
Tilburg University, Netherlands.
People tend to be bad at detecting lies: When explicitly asked to infer whether others tell a lie or the truth, people often do not perform better than chance. However, increasing evidence suggests that implicit lie detection measures and potentially physiological measures may mirror observers' telling apart lies from truths after all. Implicit and physiological responses are argued to respond to lies as a threatening stimulus associated with a threat response.
View Article and Find Full Text PDFJpn J Nurs Sci
October 2024
Department of Nursing, Mie Prefectural College of Nursing, Tsu, Japan.
Aim: This study assessed the effects of hand-bathing on sympathetic nervous activity exacerbated by psychological stress. Participants immersed one hand in warm water for 2 min while exposed to noise, and changes in blood flow and skin temperature of the non-immersed hand were observed.
Methods: Twenty-nine healthy university students aged 20 years or older were randomly assigned to either the hand-bathing group (n = 14) or the control group (n = 15).
Nanoscale
October 2024
Advanced Research Institute for Multidisciplinary Science, Beijing Institute of Technology, Beijing 100081, China.
Graphene oxide (GO)-based humidity sensors are attracting widespread attention due to their high responsivity and low cost. However, GO-based humidity sensors generally suffer from slow response and recovery as well as poor stability. Here, we report a flexible resistive humidity sensor based on a MoS/GO composite film that was fabricated by mixing different volumes of MoS and GO dispersions with adjustable volume ratios.