A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Guardian: an implantable system for chronic ambulatory monitoring of acute myocardial infarction. | LitMetric

The AngelMed Guardian is an implantable medical device that records cardiac data and detects ischemic events using a standard pacemaker intracardiac lead positioned in the right ventricular apex. The Guardian has been implanted in 55 people in the United States and Brazil and is currently undergoing a Food and Drug Administration phase 2 pivotal trial in the United States. The Guardian detects acute ischemic events by analyzing ST-segment shifts. The ST-segment shifts are calculated as the difference between the ST deviation of a current 10-second electrogram window and a baseline ST deviation value. If the ST-segment shift is greater than a heart rate-dependent programmable threshold, then the device generates an emergency alert signal. Results thus far have demonstrated that (i) the intracardiac electrogram is relatively noise-free and (ii) the ST-shift technique used by the Guardian is effective for detecting acute ischemic events.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jelectrocard.2009.06.017DOI Listing

Publication Analysis

Top Keywords

ischemic events
12
guardian implantable
8
united states
8
acute ischemic
8
st-segment shifts
8
guardian
5
implantable system
4
system chronic
4
chronic ambulatory
4
ambulatory monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!