Purpose: The aim of this study was to evaluate the in vivo tissue response to low-pressure plasma-pretreated collagen-I-coated titanium implant in a middle-term mouse model.

Methods: Plasma-treated collagen-coated titanium implants were transplanted into the dorsal skinfold chambers of BALB/c mice. Untreated, regular titanium implant material served as control. The neovascularization (functional vessel density) of the implant border zone and of the surrounding muscle tissue was analysed by intravital fluorescence microscopy. Additional histological analysis was performed to observe the inflammatory reaction.

Results: Statistical analysis revealed that the vessel density in the border zone of the implants was significantly enhanced in the plasma-treated collagen-I-coated group compared to controls. The histological examination of the two groups confirmed that the inflammatory response to the collagen-coated titanium implants was reduced compared to controls.

Conclusion: Plasma pretreatment and collagen I coating of titanium implant material leads to an enhanced tissue vascularization and a reduced inflammatory response.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000229026DOI Listing

Publication Analysis

Top Keywords

titanium implant
12
tissue response
8
plasma-treated collagen-i-coated
8
collagen-i-coated titanium
8
collagen-coated titanium
8
titanium implants
8
implant material
8
vessel density
8
border zone
8
inflammatory response
8

Similar Publications

To investigate the effect of the sizes of osteon-like concentric microgroove structures on the osteoclastic differentiation of macrophages on titanium surfaces, and to provide reference for the surface modification of implants. The silicon wafers sputtered with titanium were selected as the control group (smooth surface specimens) and four concentric groups (concentric circles with the maximum diameter of 200 μ m, the minimum diameter of 20 μ m, the spacing of concentric circles of 10 or 30 μm, the width of microgrooves of 10 or 30 μm, and the depth of microgrooves of 5 or 10 μm) specimens (the total sample size in each group was 27). The width of microgrooves of C10-5 and C10-10 groups was 10 μm, the depth was 5 and 10 μm, and the width of microgrooves of C30-5 and C30-10 groups was 30 μ m, the depth was 5 and 10 μ m, respectively.

View Article and Find Full Text PDF

Miniaturization of next-generation active neural implants requires novel micro-packaging solutions that can maintain their long-term coating performance in the body. This work presents two thin-film coatings and evaluates their biostability and in vivo performance over a 7-month animal study. To evaluate the coatings on representative surfaces, two silicon microchips with different surface microtopography are used.

View Article and Find Full Text PDF

Introduction/objectives: Failures of osseointegrated implants pose a significant challenge in the medical field, often attributed to prolonged osseointegration periods and bacterial infections. Functionalization of Titanium Dioxide Nanotubes (TNTs) has emerged as a promising strategy to improve osseointegration and mitigate infections. This study aims to conduct a bibliometric analysis and systematic review to identify trends, gaps, and advancements in research on the functionalization of TNTs for osseointegration improvement.

View Article and Find Full Text PDF

The aims of this study were twofold: first, to investigate the surface roughness of different abutment materials prepared using various manufacturing methods; and, second, to evaluate colonization by Streptococcus mutans and Candida albicans according to abutment material and manufacturing method. Six material/manufacturing method combinations were investigated in this study, namely chromium-cobalt (Cr-Co) (prepared using casting, milling, and laser sintering) and titanium, zirconia, and anodized titanium (all prepared using milling); titanium (stock) abutments were used as the control group. Surface roughness of seven specimens from each group was evaluated using atomic force microscopy and scanning electron microscopy.

View Article and Find Full Text PDF

Biophysical stimuli such as alternating electrical fields can mimic endogenous electrical potentials and currents in natural bone. This can help to improve the healing and reconstruction of bone tissue. However, little is known about the combined influence of biomaterials and alternating electric fields on bone cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!