Endovascular device specifications and technical improvements are strongly required, especially in particular anatomical locations such as the aortic arch and the thoracoabdominal aorta. We present a new technique for total endovascular repair of the aortic arch and an experimental design of a circulation model in the human cadaver in order to evaluate the feasibility of this technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2009.04.001DOI Listing

Publication Analysis

Top Keywords

human cadaver
8
aortic arch
8
dynamic human
4
cadaver model
4
model testing
4
testing feasibility
4
feasibility endovascular
4
endovascular techniques
4
techniques tools
4
tools endovascular
4

Similar Publications

In recent years, robotic assistance has become increasingly used and applied in minimally invasive surgeries. A new cooperative surgical robot system that includes a joystick-guided robotic scope holder was developed in this study, and its feasibility for use in minimally invasive abdominal surgery was evaluated in a preclinical setting. The cooperative surgical robot consists of a six-degree-of-freedom collaborative robot arm and a one-degree-of-freedom bidirectional telescopic end-effector specializing in surgical assistance.

View Article and Find Full Text PDF

Background: Streptococcus suis (S. suis) is a major swine pathogen and a significant zoonotic agent, causing substantial economic losses in the swine sector and having considerable public health importance. The control and management of S.

View Article and Find Full Text PDF

Comparison of treatments for equine laryngeal hemiplegia using computational fluid dynamic analysis in an equine head model.

Front Vet Sci

December 2024

Department of Large Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada.

Introduction: Computational fluid dynamics (CFD) is gaining momentum as a useful mechanism for analyzing obstructive disorders and surgeries in humans and warrants further development for application in equine surgery. While advancements in procedures continue, much remains unknown about the specific impact that different surgeries have on obstructive airway disorders. The objective of this study was to apply CFD analysis to an equine head inhalation model replicating recurrent laryngeal neuropathy (RLN) and four surgical procedures.

View Article and Find Full Text PDF

Objective: The endoscopic endonasal approach (EEA), has become the preferred alternative to traditional open and transoral approaches to the ventral craniovertebral junction (CVJ) region. However, preoperative prediction of the limitations of caudal reach remains challenging. This cadaveric study aimed to quantify the CVJ area of exposure and access afforded by the EEA, evaluate the accuracy of previously described radiographic anthropometric lines, and identify the lowest limit of the EEA corridor.

View Article and Find Full Text PDF

Introduction: The clinical feasibility and applicability of surface landmarks for Baxter nerve entrapment to proximal and distal sites is unclear. This study provides anatomical guidelines for optimal transducer placement using two specific landmarks, the most inferior tip of the medial malleolus (A) and the most protruding posterior tip of the calcaneus (B), to enhance the diagnostic and therapeutic injection efficacy for proximal and distal entrapment sites.

Materials And Methods: Eighty-six feet from 45 fresh cadavers (25 male and 20 female) were dissected to determine Baxter's nerve (BN) localization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!