Aims: Graft materials used for pelvic floor reinforcement should still be considered as investigational and, therefore, evaluated experimentally and within clinical trials. The present report describes our biomechanical findings in rats implanted with selected novel implant materials, which in recent years have been suggested as alternatives to plain polypropylene (PP) meshes.
Methods: Full thickness abdominal wall defects were primarily repaired by the implant of interest. Experiments involved eight different implant materials: two partly degradable synthetic implants, that is, a hybrid of polyglactin 910 with PP (Vypro II) and collagen coated PP (Pelvitex); two non-cross linked (Surgisis, InteXēn LP) and two cross-linked materials (Pelvicol, Pelvisoft) and two porous modifications of InteXēn LP and Pelvicol implants. At different time points (7, 14, 30, and 90 days), the implants and surrounding host tissue (explant) were harvested and tensiometry was performed. Tensile strength and location of breakage were recorded.
Results: In general resorbable non-cross linked collagen matrices and porous materials were weaker after 90 days; similar behavior was seen for implant materials alone and their construction with the surrounding native tissue. Both non-porous and porous modification of InteXēn LP appeared at 90 days as a very thin layer of collagen that was two-thirds, respectively one-third of the initial thickness.
Conclusions: In experimental conditions, sufficient strength was obtained only after 3 months, and PP containing constructs appeared as the strongest though reconstruction with Pelvicol showed comparable outcomes. Lower values for strength of non-cross linked and porous collagen materials are questioning their efficacy for pelvic floor reconstruction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nau.20755 | DOI Listing |
Curr Rev Musculoskelet Med
January 2025
Banner University of Arizona-Phoenix, 7400 N Dobson Rd, Scottsdale, AZ, 86256, U.S.A..
Purpose Of Review: Meniscectomy alters knee function and known to be associated with an increased incidence of knee arthritis. Several methods and materials have been tried to replicate the function of a meniscus. One is a polycarbonate-urethane synthetic medial meniscus implant labeled as NUsurface.
View Article and Find Full Text PDFJ Prosthodont
January 2025
Department of Clinical and Biological Sciences, University of Turin, Turin, Italy.
Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.
Materials And Methods: Two implant sites were prepared in the tibia of four minipigs.
J Contemp Dent Pract
October 2024
Department of Crown and Bridge, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt.
Aim: To assess hard as well as soft peri-implant tissues within cases having two lost adjacent anterior teeth treated through placing either two implants with two separate crowns or only an implant along with a crown with a cantilever, and evaluating the effect of polyetheretherketone (PEEK) restoration on cantilever design up to 18 months after functional loading.
Materials And Methods: Twenty-seven participants (15 males and 12 females; mean age, 38.6 years; range 20-50 years) with missing two adjacent anterior teeth were treated with implant system (Flotecno implant system, Italy).
J Contemp Dent Pract
October 2024
Department of Academic, Grupo de Bibliometría, Evaluación De Evidencia y Revisiones Sistemáticas (BEERS), Human Medicine Career, Faculty of Medicine, Universidad Científica del Sur, Lima, Peru, Phone: +5113171023, e-mail:
Aim: The socket-shield technique arises from the efforts to stop the dimensional changes of the bone crest and gingival tissues. This technique consists of leaving a vestibular fragment of a naturally attached root with the purpose of keeping the crestal bone nourished through the periodontium. The aim of this research was to perform a scientometric analysis of the scientific production on the socket-shield technique in oral implantology.
View Article and Find Full Text PDFJ Dent Sci
January 2025
Department of Periodontology, Nihon University School of Dentistry, Tokyo, Japan.
Background/purpose: Peri-implantitis remains a substantial challenge. This study investigated the effect of titanium particles on human oral epithelial cells, focusing on the nucleotide-binding domain and leucine-rich repeat protein (NLRP) 3 inflammasome.
Materials And Methods: The Ca9-22 human gingival epithelial cell line was subjected to incubation with titanium particles.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!