Objective: To investigate the methods of lesion localization and surgical treatment for non-palpable breast cancer, presented with only small calcification lesion on the images.
Methods: From November 2003 to August 2007, 61 patients with non-palpable lesion were finally pathologically diagnosed as early breast cancer (T1-2N0M0), based on the small calcification lesions shown by full field digital mammography (FFDM) through molybdenum target, and the rich blood supply shown by type-B ultrasonic examination. Accurate lesion-localization prior to surgical resection was conducted, and sample re-examination by FFDM was done after resection. Patients with single lesion underwent breast-conserving surgery, precise excision with the aid of image-guided wire localization, and stage I breast reconstruction was performed simultaneously using wide-based gland-tissue flap. Patients with multiple lesions received modified radical mastectomy.
Results: Among the 50 patients treated with breast-conserving surgery, the accuracy of localization for lesions was 100% (50/50), and all lesions were excised completely with a negative margin proven by FFDM re-examination and pathological examination. The superior rate of mammaplasty was 86.0% (43/50) according to JCRT criteria, with a compliance difference of 1.5 cm. Modified radical mastectomy was performed in 11 patients. The follow-up period in this series was from 6 to 58 months with a mean follow-up time of 39 months. Distant metastases were detected in only one patient and local recurrence was not observed yet.
Conclusion: Lesion localization by FFDM in patients with non-palpable breast cancer is accurate and practical. In patients with single lesion, breast-conserving resection followed by synchronous stage I breast reconstruction with wide-based gland-tissue flap is appropriate.
Download full-text PDF |
Source |
---|
Cureus
December 2024
Department of Breast, Plastic and Reconstructive Surgery, Royal Hallamshire Hospital, Sheffield, GBR.
Background The incidence of margin re-excision following breast conserving surgery (BCS) is a quality measure in the National Health Service. The threshold is less than 20% of all BCS procedures. Despite three decades of studies and a wealth of literature identifying multiple factors associated with increased risk for margin involvement, an accepted threshold rate affecting one in five procedures remains high.
View Article and Find Full Text PDFBMC Cancer
January 2025
Unité de Sénologie, Centre Jean PERRIN, Clermont-Ferrand, France.
Background: Most breast cancers are detected at an early stage in which case conservative surgery is indicated. An accurate preoperative localization technique is essential for conservative surgery of non-palpable breast lesions. Currently, the gold standard technique is wire localization (WL).
View Article and Find Full Text PDFSurgery
January 2025
Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padova, Italy.
Background: Intraoperative ultrasound-guided breast-conserving surgery guarantees real-time direct visualization of tumor and resection margins. We compared surgical, oncologic, and cosmetic outcomes between intraoperative ultrasound-guided breast-conserving surgery and traditional (palpation- or wire-guided) surgery across all breast cancer lesion types.
Methods: This prospective observational cohort study was conducted at the Veneto Institute of Oncology between January 2021 and October 2022.
Phys Med Biol
January 2025
Department of Medical Physics, Jeroen Bosch Ziekenhuis, Henri Dunantstraat 1, 's-Hertogenbosch, 5223GZ, NETHERLANDS.
The treatment of breast cancer during pregnancy requires careful consideration of consequences for both maternal and fetal health. In non-pregnant patients, the use of radioactive iodine-125 (125I)-seeds is standard practice for localising non-palpable breast tumors before breast-conserving surgery. However, the use of 125I-seeds in pregnant patients has been avoided due to concerns about fetal radiation exposure.
View Article and Find Full Text PDFEur J Radiol Open
June 2025
Radiology Department, National Cancer Institute, Cairo University, Egypt.
Purpose: To investigate the impact of artificial intelligence (AI) reading digital mammograms in increasing the chance of detecting missed breast cancer, by studying the AI- flagged early morphology indictors, overlooked by the radiologist, and correlating them with the missed cancer pathology types.
Methods And Materials: Mammograms done in 2020-2023, presenting breast carcinomas (n = 1998), were analyzed in concordance with the prior one year's result (2019-2022) assumed negative or benign. Present mammograms reviewed for the descriptors: asymmetry, distortion, mass, and microcalcifications.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!