Imaging dose from megavoltage cone beam computed tomography (MVCBCT) can be significantly reduced without loss of image quality by using an imaging beam line (IBL), with no flattening filter and a carbon, rather than tungsten, electron target. The IBL produces a greater keV-range x-ray fluence than the treatment beam line (TBL), which results in a more optimal detector response. The IBL imaging dose is not necessarily negligible, however. In this work an IBL was dosimetrically modeled with the Philips Pinnacle3 treatment planning system (TPS), verified experimentally, and applied to clinical cases. The IBL acquisition dose for a 200 degrees gantry rotation was verified in a customized acrylic cylindrical phantom at multiple imaging field sizes with 196 ion chamber measurements. Agreement between the measured and calculated IBL dose was quantified with the 3D gamma index. Representative IBL and TBL imaging dose distributions were calculated for head and neck and prostate patients and included in treatment plans using the imaging dose incorporation (IDI) method. Surface dose was measured for the TBL and IBL for four head and neck cancer patients with MOSFETs. The IBL model, when compared to the percentage depth dose and profile measurements, had 97% passing gamma indices for dosimetric and distance acceptance criteria of 3%, 3 mm, and 100% passed for 5.2%, 5.2 mm. For the ion chamber measurements of phantom image acquisition dose, the IBL model had 93% passing gamma indices for acceptance criteria of 3%, 3 mm, and 100% passed for 4%, 4 mm. Differences between the IBL- and TBL-based IMRT treatment plans created with the IDI method were dosimetrically insignificant for both the prostate and head and neck cases. For IBL and TBL beams with monitor unit values that would result in the delivery of the same dose to the depth of maximum dose under standard calibration conditions, the IBL imaging surface dose was higher than the TBL imaging surface dose by an average of 18%, with a standard deviation of 8% (p = 2 x 10(-6)). The IBL can be modeled with acceptable accuracy using a standard TPS, and accounting for IBL dose in treatment plans with the IDI method is straightforward. The resulting composite dose distributions, assuming similar imaging doses, are negligibly different from those of the TBL. The increased IBL surface dose relative to the TBL is likely clinically insignificant.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3125663DOI Listing

Publication Analysis

Top Keywords

dose
16
imaging dose
16
surface dose
16
ibl
15
head neck
12
treatment plans
12
idi method
12
imaging
10
imaging beam
8
electron target
8

Similar Publications

Background Aims: Extracellular vesicles (EVs) have gained traction as potential cell-free therapeutic candidates. Development of purification methods that are scalable and robust is a major focus of EV research. Yet there is still little in the literature that evaluates purification methods against potency of the EV product.

View Article and Find Full Text PDF

Background: Opioids are still being prescribed to manage acute postsurgical pain. Unnecessary opioid prescriptions can lead to addiction and death, as unused tablets are easily diverted.

Methods: To determine whether combination nonopioid analgesics are at least as good as opioid analgesics, a multisite, double-blind, randomized, stratified, noninferiority comparative effectiveness trial was conducted, which examined patient-centered outcomes after impacted mandibular third-molar extraction surgery.

View Article and Find Full Text PDF

Objectives: Past studies have shown the efficacy of spinal targeted drug delivery (TDD) in pain relief, reduction in opioid use, and cost-effectiveness in long-term management of complex chronic pain. We conducted a survey to determine treatment variables associated with patient satisfaction.

Materials And Methods: Patients in a single pain clinic who were implanted with Medtronic pain pumps to relieve intractable pain were identified from our electronic health record.

View Article and Find Full Text PDF

Clinical Pharmacokinetics of Atogepant in Healthy Japanese and White Adults.

Neurol Ther

January 2025

Clinical Pharmacology, AbbVie Inc., 1 North Waukegan Rd., North Chicago, IL, 60064, USA.

Introduction: Atogepant is a calcitonin gene-related peptide receptor antagonist approved for the preventive treatment of migraine in adults in the USA, EU, and several other countries. The objectives of this study were to evaluate the pharmacokinetics (PK) and dose proportionality of atogepant in healthy Japanese participants, evaluate the safety and tolerability of atogepant in Japanese participants, and explore the differences in the PK and safety of atogepant in Japanese vs white participants.

Methods: A total of 50 participants (40 Japanese and 10 white) were enrolled into five cohorts; Japanese cohorts were randomized in a 4:1 ratio to atogepant (10 mg, 30 mg, or 60 mg daily dosing and 60 mg twice daily) or placebo.

View Article and Find Full Text PDF

The aim of the present work is to investigate the photocatalytic degradation of propyl paraben (propyl para-hydroxybenzoate, PrP) using CuO-ZnO-NPs photocatalyst followed by the identification of the oxidation by-products. The CuO-ZnO-NPs material, synthesized using a green chemistry approach, was used as a photocatalyst for the removal of PrP. The nanoparticles were characterized by XRD, XRF, diffuse reflectance spectroscopy, ATG/DTG, FTIR, SEM-EDX, BET and FRX techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!