Objective: To describe a system for measurement of the pretraumatic femoral antetorsion angle post-bilateral femoral shaft fracture with the use of new imaging software which allows segmentation and three dimensional (3D) reconstruction of DICOM (digital imaging and communications in medicine) images.
Material And Methods: This case involved a 20-year-old patient with bilateral femoral shaft fractures. Following initial clinical examination, CT scans of both femurs were performed. Subsequently, the DICOM datasets were uploaded to the new software tool. Following segmentation and 3D reconstruction, pretraumatic femoral antetorsion angles were determined.
Results: Femoral antetorsion was described and assessed in two ways by referring to the intersection of the posterior condylar plane and (1) a line drawn between the center of the femoral head and femoral neck, (2) a line drawn between the centers of the femoral head and greater trochanter. Using these definitions, values for femoral antetorsion were found to be, respectively, 20 degrees at the right fracture site and 19 degrees on the left site, and 33 degrees bilaterally.
Discussion: The investigators describe in this current technical report the use of new imaging software which enables the calculation of femoral AV following reduction of virtual fracture fragments which are created from standard DICOM images. We believe that this 3D reconstruction method of measuring the antetorsion angle can be integrated into a regular treatment algorithm and may potentially optimize clinical outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00256-009-0748-0 | DOI Listing |
Res Vet Sci
January 2025
Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians University Munich, Germany. Electronic address:
This study aims to provide an initial database to gain more detailed knowledge of the trabecular and cortical bone structure of pelvic and femur bones in cats and smaller dogs. Additionally, the bony microarchitecture between cats and smaller dogs was compared to identify possible differences between those species. These findings could potentially improve the development of non-cemented total hip replacement (THR).
View Article and Find Full Text PDFArthroscopy
October 2024
Editorial Board (B.G.D.); Chicago, Illinois (I.A.W., N.B.); Hannover, Germany (N.B.).
J Clin Med
October 2024
SC Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, via Pupilli 1, 40136 Bologna, Italy.
Front Endocrinol (Lausanne)
October 2024
Department of Pediatric Orthopedics, Orthopedic Hospital Speising, Vienna, Austria.
Hip Int
November 2024
OKL, Luzern, Switzerland.
Background And Purpose: Metaphyseal-stabilised short stems rely on sufficient metaphyseal fixation and are inserted by following the medial cortex. This type of stem is used extensively in our institution, and we observed on occasion unintended implant positioning with an increased distance between the implant and the medial cortex. A bony structure within the proximal femur which was first described in 1874 and named the calcar femorale, coincides with this phenomenon.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!