The electronic excitation spectra of trans-1,3-butadiene (CH(2)=CH-CH=CH(2)) and trans-2-propeniminium (CH(2)=CH-CH=NH(2)(+)) have been studied at several coupled-cluster and time-dependent density functional theory levels using the linear response approach. Systematic studies employing large correlation-consistent basis sets show that approximate singles and doubles coupled-cluster calculations yield excitation energies in good agreement with experiment for all states except for the two lowest excited A(g) states of trans-1,3-butadiene which have significant multiconfigurational character. Time-dependent density functional theory calculations employing the generalized gradient approximation and hybrid functionals yield too low excitation energies in the basis set limit. In trans-1,3-butadiene, increasing the basis set size by augmenting multiple diffuse functions is observed to reduce the high-lying excitation energies with most density functionals. The decrease in the energies is connected to the incorrect asymptotic behavior of the exchange-correlation potential. The results also demonstrate that standard density functionals are not capable of providing excitation energies of sufficient accuracy for experimental assignments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.3158990 | DOI Listing |
Using the first principle calculations, we propose a boron and nitrogen cluster incorporated graphene system for efficient valley polarization. The broken spatial inversion symmetry results in high Berry curvature at and valleys of the hexagonal Brillouin zone in this semiconducting system. The consideration of excitonic quasiparticles within the approximation along with their scattering processes using the many-body Bethe-Salpeter equation gives rise to an optical gap of 1.
View Article and Find Full Text PDFThe GSAG:Ce scintillator represents a promising and cost-effective alternative to the expensive GGAG:Ce. Recent studies have attributed its low light yield to the thermal quenching effect. In this study, we employed the strategy of adding an yttrium (Y) admixture to the GSAG matrix to increase the thermal activation energy of thermal quenching.
View Article and Find Full Text PDFHeliyon
January 2025
Institute of Biomedicine of Málaga (IBIMA), 29010, Málaga, Spain.
Background: Chronic kidney disease is a global problem characterized by a progressive decrease in kidney function with associated symptoms. A better understanding of these symptoms could lead to the development of personalized strategies.
Objective: This systematic review aims to describe the clusters of symptoms in kidney failure and categorize them according to their time of onset and how disabling they are for patients.
Chemistry
January 2025
Middle East Technical University: Orta Dogu Teknik Universitesi, Chemistry, Universiteler Mah., 06800, Cankaya, TURKEY.
This study introduces a new donor group capable of activating click-type [2+2] cycloaddition-retroelectrocyclizations, generally known for their limited scope. Target chromophores were synthesized using isocyanate-free urethane synthesis. The developed synthetic method allows for the tuning of the optical properties of the chromophores by modifying the donor groups, the acceptor units, and the side chains.
View Article and Find Full Text PDFSe Pu
February 2025
CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
Chemical modifications are widely used in research fields such as quantitative proteomics and interaction analyses. Chemical-modification targets can be roughly divided into four categories, including those that integrate isotope labels for quantification purposes, probe the structures of proteins through covalent labeling or cross-linking, incorporate labels to improve the ionization or dissociation of characteristic peptides in complex mixtures, and affinity-enrich various poorly abundant protein translational modifications (PTMs). A chemical modification reaction needs to be simple and efficient for use in proteomics analysis, and should be performed without any complicated process for preparing the labeling reagent.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!