A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Home monitoring in patients with implantable cardiac devices: is there a potential reduction of stroke risk? Results from a computer model tested through monte carlo simulations. | LitMetric

Introduction: Patients with pacemakers and implantable defibrillators (ICD) may experience asymptomatic atrial fibrillation (AF), detected with a delay depending on the in-person follow-up schedule. Home monitoring (HM) remote control with automatic alerts for AF may drive early anticoagulation, potentially reducing stroke risk.

Methods And Results: A sample of 136 pacemaker (103) and ICD (33) patients with or without cardiac resynchronization therapy not taking anticoagulation at implant were monitored remotely with HM. Upon HM alerts for AF, patients were recalled to update therapy. Two-year data were entered in a computer Monte Carlo model, simulating 4,000 virtual subjects with the same AF and CHADS(2) stroke risk distribution of our real population. Simulations reproduced a 2-year follow-up. Two thousand subjects were supposed to be followed with HM (HM group) and 2,000 with standard in-person follow-up (SF group) at 3, 6, 9, or 12 months. Two-year Kaplan-Meier cumulative probability of >/=24-hour AF was 15.6% (95%CI 8.5-23.3%); the AF-related symptom rate was 27% and the median CHADS(2) score was 2. As a result of simulations, stroke incidence in case of AF was 2.3 +/- 1.1% in the HM group and 2.4 +/- 1.1%, 2.5 +/- 1.2%, 2.7 +/- 1.2%, and 2.9 +/- 1.3% in the SF group with 3-, 6-, 9-, and 12-month follow-up programs, with odds ratios of 0.97 (95%CI 0.93-1.01), 0.91 (0.88-0.95), 0.87 (0.84-0.90), and 0.82 (0.79-0.85) (HM better if odds ratios <1), respectively.

Conclusions: Daily HM potentially reduces the stroke risk by 9% to 18% with respect to SF with intervisit intervals of 6 to 12 months.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8167.2009.01543.xDOI Listing

Publication Analysis

Top Keywords

monte carlo
8
in-person follow-up
8
+/- 11%
8
+/- 12%
8
12% +/-
8
odds ratios
8
+/-
5
monitoring patients
4
patients implantable
4
implantable cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!