A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed.

Download full-text PDF

Source
http://dx.doi.org/10.2302/kjm.58.120DOI Listing

Publication Analysis

Top Keywords

stereotactic radiosurgery
8
partial denture
8
upper jaw
8
biteplate autopolymerizing
8
autopolymerizing resin
8
biteplate
6
radiosurgery upper
4
upper partial
4
denture 54-year-old
4
54-year-old male
4

Similar Publications

Introduction: The role of stereotactic radiosurgery (SRS) in pituitary adenomas (PAs) is evolving especially considering its safety. Existing literature is hampered by limited sample sizes and short-term follow-ups, impeding its preeminence in the clinical and radiological outcomes. We propose a comprehensive, single-centred study to evaluate the outcomes following CyberKnife stereotactic radiosurgery (CK SRS) for PAs in a larger patient population, incorporating meticulous clinical and radiological follow-up.

View Article and Find Full Text PDF

Introduction: SRS for the treatment of limited brain metastases (BM) is widely accepted, but there are still limitations in the management of numerous BM. Frameless single-isocenter multitarget SRS is a novel technique that allows for rapid treatment delivery to multiple BM. We report our preliminary clinical, dosimetric, and patient´s shifts outcomes with this technique.

View Article and Find Full Text PDF

Aortic intimal sarcoma is a rare disease with no established treatment and a poor prognosis. A 70-year-old man who underwent surgery for a mass shadow extending from the ascending aorta to the left common carotid artery on contrast-enhanced computed tomography was diagnosed with intimal sarcoma and underwent postoperative radiotherapy (66 Gy/33 Fr). Three brain metastases were identified after 1.

View Article and Find Full Text PDF

This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!