The aim of this study was to investigate whether impaired ankle function after total ankle arthroplasty (TAA) affects the mechanical work during the step-to-step transition and the metabolic cost of walking. Respiratory and force plate data were recorded in 11 patients and 11 healthy controls while they walked barefoot at a fixed walking speed (FWS, 1.25 m/s) and at their self-selected speed (SWS). At FWS metabolic cost of transport was 28% higher for the TAA group, but at SWS there was no significant increase. During the step-to-step transition, positive mechanical work generated by the trailing TAA leg was lower and negative mechanical work in the leading intact leg was larger. Despite the increase in mechanical work dissipation during double support, no significant differences in total mechanical work were found over a complete stride. This might be a result of methodological limitations of calculating mechanical work. Nevertheless, mechanical work dissipated during the step-to-step transition at FWS correlated significantly with metabolic cost of transport: r=.540. It was concluded that patients after successful TAA still experienced an impaired lower leg function, which contributed to an increase in mechanical energy dissipation during the step-to-step transition, and to an increase in the metabolic demand of walking.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.humov.2009.05.001DOI Listing

Publication Analysis

Top Keywords

mechanical work
32
step-to-step transition
20
metabolic cost
16
mechanical
9
work
8
work step-to-step
8
total ankle
8
ankle arthroplasty
8
cost transport
8
increase mechanical
8

Similar Publications

Smooth braking control of excavator hydraulic load based on command reshaping.

ISA Trans

January 2025

School of Mechanical Engineering, Dongguan University of Technology, Dongguan 523015, China; School of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, China. Electronic address:

Excavators, a type of human-operated construction machinery, suffer from poor hydraulic load braking stability, which seriously affects operator comfort. To address this challenge, this study investigates load braking laws through model analysis and designs an open-loop control algorithm called command reshaping, which can prolong the small-opening time of the main valve by segmentally adjusting the joystick command during load braking and then actively adjusting the key parameters reflecting the system's kinetic-potential energy state, thereby suppressing braking oscillations. The experimental results based on a 1.

View Article and Find Full Text PDF

Objectives: To characterize two experimental zirconia bilayer materials compared to their monolithic controls, before and after hydrothermal aging.

Methods: Commercial zirconia powders were utilized to fabricate two bilayer materials: 3Y-TZP+ 5Y-PSZ (3Y+5Y/BI) and 4Y-PSZ+ 5Y-PSZ (4Y+5Y/BI), alongside control groups 3Y-TZP (3Y/C), 4Y-PSZ (4Y/C), and 5Y-PSZ (5Y/C). Compacted specimens were sintered (1550 °C- 2 h, 3 °C/min), and half of them underwent hydrothermal aging (134 °C-20h, 2.

View Article and Find Full Text PDF

This study aimed to develop patches containing quercetin-loaded microcapsules and to evaluate their in vitro and in vivo safety and efficacy in preclinical surveys. A set of in vitro experiments evidenced the virucidal activity of quercetin against the HSV-1-KOS (sensitive to acyclovir) and HSV-1-AR (resistant to acyclovir) strains, with improved outcomes upon the first. The patches presented a homogeneous aspect, were easily handled, had a suitable bioadhesion, and possessed mechanical properties of soft and weak material, besides a pH compatible with human skin.

View Article and Find Full Text PDF

Purpose: Cigarette smoking (CS) induces systemic changes that impair cardiorespiratory and muscular function both at rest and during exercise. Although these abnormalities are reported in sedentary, middle-aged smokers (SM) with pulmonary disease, few and controversial studies focused on young, physically active SM at the early stage of smoking history. This study aimed at assessing the impact CS on cardiorespiratory and metabolic response during an incremental test and the subsequent recovery in young, physically active SM without known lung or cardiovascular disease.

View Article and Find Full Text PDF

Optimized detection of calcium ion in serum using constant potential coulometry with metastable liquid-liquid contact doping enhanced PEDOT: PSS ink.

Bioelectrochemistry

January 2025

School of Chemistry, Sun Yat-Sen University, Guangzhou 510275, People's Republic of China; Key Laboratory for Polymeric Composite & Functional Materials of Ministry of Education, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, People's Republic of China.

Highly stable calcium ion selective electrodes (Ca-ISEs) were developed by drop-casting a layer of poly(3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT: PSS) as an ion-to-electron transfer layer onto Au electrode. The conductive PEDOT: PSS ink was prepared using a metastable liquid-liquid contact (MLLC) doping method, which induced phase separation, removed excess PSS, and significantly enhanced charge transfer kinetics and conductivity. The resulting Ca-ISEs exhibited excellent electrochemical performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!