We present a modified hybrid technique that is a combination of a transglenoid and suture anchor technique. Three-dimensional CT reconstruction is indicated for patients with bony fragments larger than 10 mm. First, a transglenoid technique is performed to reduce the bony fragment and then a suture anchor technique is performed to achieve a stable fixation. This combined technique is a useful arthroscopic procedure for the easy reduction and stable fixation of bony Bankart lesions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00167-009-0845-6 | DOI Listing |
This prospective, observational cohort study compares the clinical and radiographic outcomes of the modified Weaver and Dunn (WD) technique with the newer, anatomical double-button plus tendon allograft technique (DB), and the suture anchor repair plus tendon allograft (SA). The study cohort includes 53 patients, who underwent surgery for acromioclavicular joint (ACJ) dislocation Rockwood type 3, 4 and 5. Patient-reported outcome scores and clinical results, including Disabilities of the Arm, Shoulder and Hand (DASH), the Subjective Shoulder Value (SSV), the Visual Analogue Scale (VAS) and the Constant score (CS) results as well as loss of reduction rates on plain radiographs were compared.
View Article and Find Full Text PDFPak J Med Sci
January 2025
Zhenfeng Huang Department of Orthopedic Trauma, Wuhan Fourth Hospital, Wuhan, Hubei Province 430000, P.R. China.
Objective: To explore the therapeutic effect of titanium locking plate combined with suture anchor (SA) repair in the treatment of proximal humeral fractures (PHF).
Methods: This retrospective study was conducted by analyzing the clinical data of 113 patients with PHF admitted to Wuhan Fourth Hospital from March 2021 to October 2023. Among them, 55 patients underwent open reduction and internal fixation (OR/IF) using titanium locking plate (OR/IF group), and 58 patients underwent surgery with titanium locking plate combined with SA (SA group).
PeerJ
January 2025
College of Engineering, University of Tennessee - Knoxville, TN, United States of America.
Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.
Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, = 8), or four/five weeks after (delayed replacement, = 4) resection of the biological tendon.
Arch Orthop Trauma Surg
January 2025
Training Center for Emergency Medicine (NOTIS E.V), Engen, Germany.
Introduction: More extensive and cohesive studies on quadriceps tendon rupture (QTR) repair surgery are required to guide effective treatment strategies. Therefore, in this study, we aimed to identify predictors of subjective functional recovery following QTR repair surgery.
Materials And Methods: This multicentre retrospective cohort study enrolled 191 adults (age ≥ 18 years) who underwent surgical unilateral QTR repair (2010-2022) and had ≥ 1-year postoperative follow-up at three trauma centres in Germany.
Arch Bone Jt Surg
January 2024
Department of Orthopedic Surgery, 5th Azar hospital, Golestan University of Medical Sciences, Gorgan, Iran.
Objectives: Anterior shoulder instability with minimal glenoid bone loss has several options for Bankart repair. We aimed to evaluate the results of a modified technique using two anchors with double and single loaded suture (three stitches in total) in arthroscopic Bankart surgery.
Methods: Thirty-eight patients underwent arthroscopic Bankart surgery and were assessed after an average 40 months follow-up.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!