AI Article Synopsis

Article Abstract

Beta+-sensitive probes are useful tools for the measurement of radiotracer kinetics in small animals. They allow the cost-effective development of new PET tracers and offer the possibility to investigate a variety of cerebral processes. The study's main aim was the in vivo evaluation of a probe system for cerebral surface acquisitions. The detector system is a 0.2-mm thick scintillating disk of 3-mm diameter, positioned close to the cerebral surface. The study consists of 4 subparts: (1) simulation of the detection volume, (2) direct comparison with the classic intracortical beta probe regarding its capability to acquire kinetic data, (3) test of the ability to detect local tracer accumulations during infraorbital nerve (ION) electrostimulation and (4) demonstration of the feasibility to measure tracer kinetics in awake animals. Kinetic data acquired with 18F-fluorodeoxyglucose and 15O-H2O were fitted with standard compartment models. The surface probe measurements were in good agreement with those obtained using the intracortical scintillator. ION electrostimulation induced a marked increase in tracer accumulation adequately detected by the surface probe. In the head-fixed animal, a marked change in FDG kinetics was detected between the awake and anesthetized state. The novel surface probe system proved to be a valuable instrument for in vivo radiotracer studies of the cerebral cortex. Its main advantage is the absence of any tissue damage. In addition, serial acquisitions of tracer kinetics in the awake animal turned out to be feasible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2009.06.077DOI Listing

Publication Analysis

Top Keywords

surface probe
12
radiotracer kinetics
8
probe system
8
cerebral surface
8
kinetic data
8
ion electrostimulation
8
tracer kinetics
8
kinetics awake
8
kinetics
5
probe
5

Similar Publications

Atomic force microscopy-infrared spectroscopy (AFM-IR) is a photothermal scanning probe technique that combines nanoscale spatial resolution with the chemical analysis capability of mid-infrared spectroscopy. Using this hybrid technique, chemical identification down to the single molecule level has been demonstrated. However, the mechanism at the heart of AFM-IR, the transduction of local photothermal heating to cantilever deflection, is still not fully understood.

View Article and Find Full Text PDF

Experiencing music often entails the perception of a periodic beat. Despite being a widespread phenomenon across cultures, the nature and neural underpinnings of beat perception remain largely unknown. In the last decade, there has been a growing interest in developing methods to probe these processes, particularly to measure the extent to which beat-related information is contained in behavioral and neural responses.

View Article and Find Full Text PDF

Mapping Surface Potential in DNA Aptamer-Neurochemical and Membrane-Ion Interactions on the SOS Substrate Using Terahertz Microscopy.

Biosensors (Basel)

January 2025

Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8530, Japan.

In this study, we utilized a terahertz chemical microscope (TCM) to map surface potential changes induced by molecular interactions on silicon-on-sapphire (SOS) substrates. By functionalizing the SOS substrate with DNA aptamers and an ion-selective membrane, we successfully detected and visualized aptamer-neurochemical complexes through the terahertz amplitude. Additionally, comparative studies of DNA aptamers in PBS buffer and artificial cerebrospinal fluid (aCSF) were performed by computational structure modeling and terahertz measurements.

View Article and Find Full Text PDF

A Sensitive and Selective Electrochemical Aptasensor for Carbendazim Detection.

Biosensors (Basel)

January 2025

School of Science, Computing, and Engineering Technology, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.

Carbendazim (CBZ) is used to prevent fungal infections in agricultural crops. Given its high persistence and potential for long-term health effects, it is crucial to quickly identify pesticide residues in food and the environment in order to mitigate excessive exposure. Aptamer-based sensors offer a promising solution for pesticide detection due to their exceptional selectivity, design versatility, ease of use, and affordability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!