Background: Oesophageal anastomotic leakage is associated with considerable morbidity and mortality. The aim of the present study was to assess the feasibility of using temporary self-expanding plastic stents to treat postoperative oesophageal leaks.

Methods: Patients with anastomotic leakage after abdominothoracic oesophagectomy treated by endoscopic insertion of self-expanding plastic stents between 2001 and 2007 were studied. Clinical outcomes were analysed, including healing of the leak, morbidity and mortality.

Results: Stents were inserted successfully in all 22 patients without procedure-related complications. Ten patients also required computed tomography-guided drainage because surgical drains had been removed. Non-ventilated patients received oral nutrition a mean of 4 days after stent placement. Combined treatment with stenting and drainage resulted in resolution of the leak in 21 of 22 patients. The mean healing time (time to stent removal) was 23 days. Stent migration occurred in five of 22 patients, but endoscopic reintervention with placement of a new stent was successful in all patients. Repeat thoracotomy with intraoperative stent placement was necessary in one patient with an oesophagocolonic anastomosis. One patient died in hospital.

Conclusion: In combination with effective drainage, self-expanding plastic stents are an option for the treatment of oesophageal anastomotic leaks, and may reduce leak-related morbidity and mortality.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bjs.6648DOI Listing

Publication Analysis

Top Keywords

self-expanding plastic
16
plastic stents
16
oesophageal anastomotic
12
treatment oesophageal
8
anastomotic leaks
8
anastomotic leakage
8
morbidity mortality
8
days stent
8
stent placement
8
patients
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!