A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Potential for contamination during removal of radioactive seeds from surgically excised tissue. | LitMetric

Potential for contamination during removal of radioactive seeds from surgically excised tissue.

Health Phys

Mayo Clinic, Radiation Safety, Department of Facilities Services, Mayo Clinic, Medical Sciences Building B-28, Rochester, MN 55905, USA.

Published: August 2009

The purpose of this study was to determine whether the use of a scalpel or electrocautery to remove radioactive sealed sources ("seeds") from surgically excised tissue could damage the seed and cause it to leak its radioactive contents. Attempts were made to cut or burn Oncura Model 6711 non-radioactive seeds while in pig muscle or on a stainless steel plate. Additionally, one active 125I seed was purposely charred using pressure with an electrocautery knife to see whether the casing could be damaged. Electron microscopy scanning was performed on the dummy seeds to determine if the integrity of the metal casing had been compromised. Two types of leak tests were performed on the active seed to verify the presence or absence of loose contamination. The seed casing was not damaged from either use of a scalpel or electrocautery when the seed was in tissue. The active seed was not found to be leaking after applying pressure with an electrocautery knife while the seed was on a stainless steel plate. We conclude that removal of active Model 6711 seeds from surgically excised tissue can be done safely with a scalpel or electrocautery because constant, firm pressure cannot be applied to the seed. This is likely true for seeds made of similar materials.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.HP.0000348459.02616.41DOI Listing

Publication Analysis

Top Keywords

surgically excised
12
excised tissue
12
scalpel electrocautery
12
seeds surgically
8
seed
8
model 6711
8
stainless steel
8
steel plate
8
pressure electrocautery
8
electrocautery knife
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!