Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: We have assessed the kinetics of drug release in relation to the full or partial hydration and swelling of matrices under standard and modified United States Pharmacopeia (USP) apparatus II using a novel index, defined as the symmetrical shape factor. The symmetrical shape factor describes the regularity of the hydration rate of the matrix perimeter relative to its central regions.
Methods: Monolithic and three-layer matrices based on hypromellose, polyethylene oxide, Kollidon SR, theophylline, diltiazem hydrochloride and alfuzosin hydrochloride were subjected to dissolution testing.
Key Findings: Our results indicated that Kollidon SR matrices and the three-layer composite systems with and without effervescing components were not significantly affected by the dissolution conditions. However, in the case of the floating monolithic systems based on hypromellose and polyethylene oxide, both release profiles and swelling dynamics in accordance with the similarity factor (f(2)) and symmetrical shape factor values were significantly influenced.
Conclusions: The symmetrical shape factor values were positively impacted. Consequently the drug release kinetics were more predictable and reproducible. The modified USP method resulted in a more synchronized axial and radial swelling with symmetrical shape factor values approaching unity. Data further indicated that the modified USP method provided for complete matrix hydration and swelling as the dosage form remained fully submerged, allowing for more reliable release mimicking the in-vivo conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1211/jpp/61.07.0004 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!