In the frame of a technological research and innovation network in water and environment technologies (RITEAU, Réseau de Recherche et d'Innovation Technologique Eau et Environnement), our research group, in collaboration with industrial partners and other research institutions, has been in charge of the development of a suitable flowmeter: an ultrasonic device measuring simultaneously the water flow and the concentration of size classes of suspended particles. Working on the pulsed ultrasound principle, our multi-frequency device (1 to 14 MHz) allows flow velocity and water height measurement and estimation of suspended solids concentration. Velocity measurements rely on the coherent Doppler principle. A self developed frequency estimator, so called Spectral Identification method, was used and compared to the classical Pulse-Pair method. Several measurements campaigns on one wastewater collector of the French city of Strasbourg gave very satisfactory results and showed smaller standard deviation values for the Doppler frequency extracted by the Spectral Identification method. A specific algorithm was also developed for the water height measurements. It relies on the water surface acoustic impedance rupture and its peak localisation and behaviour in the collected backscattering data. This algorithm was positively tested on long time measurements on the same wastewater collector. A large part of the article is devoted to the measurements of the suspended solids concentrations. Our data analysis consists in the adaptation of the well described acoustic behaviour of sand to the behaviour of wastewater particles. Both acoustic attenuation and acoustic backscattering data over multiple frequencies are analyzed for the extrapolation of size classes and respective concentrations. Under dry weather conditions, the massic backscattering coefficient and the overall size distribution showed similar evolution whatever the measurement site was and were suggesting a global wastewater particles behaviour. By comparison to sampling data, our data analysis lead to the characterization of two particle groups: the ones occurring during rain events and the ones typical of wastewater under dry weather conditions. Even with already encouraging results on the several weeks of data recorded on several wastewater collectors, the validation of our data inversion method is still under progress.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2166/wst.2009.281 | DOI Listing |
Aesthet Surg J
January 2025
Careggi University Hospital, Florence, Italy.
Background: Preservation rhinoplasty, particularly dorsal preservation, has gained prominence with the advent of piezoelectric instruments, which minimize trauma and enhance precision in bone reshaping. This approach presents unique challenges, especially in closed techniques, where spatial limitations complicate the use of piezotomes.
Objectives: To evaluate outcomes of piezo-assisted preservation rhinoplasty using specialized instrumentation to enhance visibility, precision, and postoperative recovery in closed rhinoplasty procedures.
J Vasc Surg Cases Innov Tech
April 2025
Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Case Western Reserve University School of Medicine, University Hospitals Harrington Heart and Vascular Institute, Cleveland, OH.
Transaortic endarterectomy (TE) is an effective and durable method of restoring patency in the aorta afflicted with atherosclerotic disease, which most commonly affects the infrarenal aorta and common iliac artery. When the suprarenal aorta is involved, the disease is usually confined to the orifices of the visceral vessels without obstruction of the aortic lumen. In rare cases, dense, calcified, exophytic, and amorphous lesions causing severe luminal obstruction, termed coral reef atherosclerosis (CRA) of the suprarenal aorta, may occur.
View Article and Find Full Text PDFACS Nano
January 2025
Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital School of Medicine, Shanghai Jiao Tong University, Shanghai 200011, China.
Lymphedema, a severe and complex inflammatory disease caused by lymphatic system insufficiency and impeded lymphatic drainage that causes an enormous physical and psychological burden on patients and may even lead to death, has long been a challenging issue in the medical field. Clinically, conventional approaches including surgical treatment and conservative treatment have been employed for lymphedema therapy, but their curative effect is still unsatisfactory because of high operational difficulty, high cost, and long-term reliance. In this study, a novel kind of piezoelectric microneedle driven by ultrasound (US) is proposed to regulate macrophage polarization and remodel the pathological inflammatory microenvironment in a noninvasive manner, thereby promoting lymphatic regeneration and improving lymphedema.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
January 2025
Hibino Laboratory, University of Chicago Medicine, Chicago, IL, USA.
With the increase of patients with adult congenital heart disease, the number of high-risk multiple redo sternotomies is increasing. Calcified conduit embedded in the sternum or large vessels attached to the sternum presents an especially challenging case. This video tutorial presents a simple safe redo sternotomy technique using an ultrasonic bone scalpel in such high-risk patients.
View Article and Find Full Text PDFInt J Surg
December 2024
Department of Surgery, Sapienza University of Rome, Rome.
Background: One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves' injury. The "clamp and tie" technique was first introduced in the 19th century.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!