Objective: In the previous decade, several reports have been published regarding implants inserted in autografts, but none have analyzed implants inserted in fresh-frozen bone allografts. Thus, a retrospective study was planned to verify if 4-months' delay from grafting to implant insertion is a safe period before prosthetic rehabilitation of implants placed in fresh-frozen bone allografts.
Method And Materials: Between December 2003 and December 2006, 22 patients (10 women and 12 men with a median age of 51 years) underwent grafting with horizontal augmentation without membrane and 88 implants inserted thereafter. The mean implant follow-up was 27 months. Implants used were 30 double etched (3i, Osseotite, Biomet), 10 SLA1 (Astratech), 26 anodic oxidized (Nobel Biocare), 12 CaPO4 ceramic-blasted (Lifecore Biomedical), 7 SLA2 (Sweden and Martina Spa), 2 ITI (Straumann), and 1 Biotec (Povolaro di Dueville). Implant diameter and length ranged from 3.25 to 5.0 mm and from 8.0 to 15.0 mm, respectively. Implants were inserted to replace 10 incisors, 7 canines, 36 premolars, and 35 molars.
Results: No implants were lost (ie, survival rate = 100%). No difference was detected when comparing implants loaded after 4 months versus those loaded after 6 or more months (209 implants).
Conclusion: Four-months' delay from grafting to implant insertion is a safe period to obtain a high survival rate and success rate for implants inserted in fresh-frozen bone.
Download full-text PDF |
Source |
---|
Large-diameter heads (LDHs) in total hip arthroplasty (THA) enhance range of motion but require thinner liners. Monoblock acetabular components with ceramic liners could reduce liner fracture risks during modular acetabular component assembly. This study aims to confirm the safety and clinical performance of the monoblock Maxera Cup in THA.
View Article and Find Full Text PDFBMC Oral Health
January 2025
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Disease, Department of Orthodontics, School of Stomatology, the Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shanxi, China.
Background: To improve the success rate of mini-implants, some surgical guides have been developed through digital technologies to achieve three-dimensional (3D) guided mini-implants insertion. However, there is no a surgical guide which can be applied for the insertion of infrazygomatic mini-implant. In this study, we introduced a two-trajectories surgical guide and investigated the success rate of infrazygomatic mini-implants under the guidance of the template.
View Article and Find Full Text PDFJ Oral Implantol
January 2025
Department of Neuroscience, Reproductive Sciences and Dentistry, Federico II University of Naples, Naples, Italy.
Purpose: This pilot study evaluated and compared histomorphometric and immunohistochemical characteristics of peri-implant bone tissue after implant site preparation using piezoelectric tips versus conventional drills.
Material And Methods: Six patients with bilateral partial edentulism underwent a splitmouth protocol. Twelve alveolar ridges were randomized into six control implant sites prepared using conventional drills (Drill Group); and six test implant sites prepared using piezoelectric implant inserts (Piezo Group).
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.
Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Ophthalmology and Visual Science, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku City, 783-8505, Kochi, Japan.
To assess the efficacy of using a nylon suture as a stent in the PreserFlo MicroShunt (PMS) lumen to prevent postoperative hypotony, 59 eyes that underwent PMS implantation with follow-up for > 6 months were analyzed. Patients were divided into no intrastenting (NST) and intrastenting (ST) groups, with the ST group subdivided into 9 - 0 nylon suture fully placed (9 F), 9 - 0 nylon suture placement in only half of the lumen (9 H), 10 - 0 nylon suture fully placed (10 F), and 10 - 0 nylon suture placement in only half of the lumen (10 H). The distribution was as follows: 23 eyes in the NST group, 10 in the 9 F group, 9 in the 9 H group, 11 in the 10 F group, and 6 in the 10 H group.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!