In December 2008, the International Society for Clinical Hemorheology organized a workshop to evaluate and compare three ektacytometer instruments for measuring deformability of red blood cells (RBC): LORCA (Laser-assisted Optical Rotational Cell Analyzer, RR Mechatronics, Hoorn, The Netherlands), Rheodyn SSD (Myrenne GmbH, Roetgen, Germany) and RheoScan-D (RheoMeditech, Seoul, Korea). Intra-assay reproducibility and biological variation were determined using normal RBC, and cells with reduced deformability (i.e., 0.001-0.02% glutaradehyde (GA), 48 degrees C heat treatment) were employed as either the only RBC present or as a sub-population. Standardized difference values were used as measure of the power to detect differences between normal and treated cells. Salient results include: (1) All instruments had intra-assay variations below 5% for shear stress (SS)>1 Pa but a sharp increase was found for Rheodyn SSD and RheoScan-D at lower SS; (2) Biological variation was similar and markedly increased for SS<3-5 Pa; (3) All instruments detected GA-treated RBC with maximal power at 1-3 Pa, the presence of 10% or 40% GA-modified cells, and the effects of heat treatment. It is concluded that the LORCA, Rheodyn SSD and RheoScan-D all have acceptable precision and power for detecting reduced RBC deformability due to GA treatment or heat treatment, and that the SS range selected for the measurement of deformability is an important determinant of an instrument's power.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BIR-2009-0536DOI Listing

Publication Analysis

Top Keywords

rheodyn ssd
8
biological variation
8
comparison three
4
three commercially
4
commercially ektacytometers
4
ektacytometers shearing
4
shearing geometries
4
geometries december
4
december 2008
4
2008 international
4

Similar Publications

Blood rheology during normal pregnancy.

Clin Hemorheol Microcirc

June 2018

Department of Obstetrics and Gynecology, City Hospital of Aschaffenburg, Aschaffenburg, Germany.

Introduction: Recent studies have shown increased RBC aggregation and no difference in plasma viscosity in the presence of markedly lower hematocrit in women at term compared to non-pregnant women. Little is known about the outcome of blood rheological parameters and red blood cell (RBC) deformability particularly in the course of normal pregnancy.

Methods: During a 36 months interval 1.

View Article and Find Full Text PDF

Background: The dromedary camel and the oryx antelope are exposed to excessive heat and solar radiation in their desert habitat. Desertification of areas with by now little rainfall may occur eventually. Well-adapted large animal species show us what is needed to survive in scorching regions.

View Article and Find Full Text PDF

Our aim was to evaluate nitric oxide metabolites (nitrite and nitrate), expressed as NOx, and erythrocyte deformability, expressed as elongation index, in a group of subjects with obstructive sleep apnea syndrome (OSAS). We enrolled 48 subjects (36 men and 12 women; mean age 50.3±14.

View Article and Find Full Text PDF

Increased RDW has been found to be a marker of adverse outcomes in cardiovascular disease (CVD), although the exact mechanism remains unclear. Recently, several authors have found that higher RDW is associated with decreased erythrocyte deformability, which can impair blood flow through microcirculation, a fact which may explain the increased risk for CVD events associated with elevated RDW. The aim of the present study was to investigate the association between RDW and erythrocyte deformability in patients with acute myocardial infarction (AMI).

View Article and Find Full Text PDF

Rheological properties of homozygous sickle cell anaemia (SCA) show marked heterogeneity, which may be explained in part by the concomitance of alpha genotypes or beta haplotypes, along with hydroxurea (HU) treatment. To further clarify this issue, in 11 homozygous patients with SCA in the steady state and in 16 healthy controls, we analysed erythrocyte deformability (ED) in a Rheodyn SSD by means of the Elongation Index (EI) at 12, 30 and 60 Pa, and erythrocyte aggregation at stasis (EA0) and at 3 sec-1 (EA1) in a Myrenne aggregometer along with fibrinogen, biochemical and haematological parameters. When compared with controls, homozygous (SS) patients showed a lower EI at all the shear stresses tested (p < 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!