Implant design is one of the parameters for achieving successful primary stability. This study aims to examine the effect of a self-tapping blades implant design on initial stability in tapered implants. Polyurethane blocks of different densities were used to simulate different bone densities. The two different implant designs included one with self-tapping blades and one without self-tapping blades. Implants were placed at 3 different depths: apical third, middle third, and fully inserted at 3 different densities of polyurethane blocks. A resonance frequency (RF) analyzer was then used to measure stability of the implants. Repeated-measures analysis of variance was used to examine the effect of implant design, insertion depth, and block density on RF. Analysis of covariance was used to examine the strength of association between RF and the aforementioned factors. In both medium-density (P = .017) and high-density (P = .002) blocks, fully inserted non-self-tapping implants showed higher initial stability than self-tapping implants. No differences were noted between the 2 implant designs that were not fully inserted. The highest strength of association was with insertion depth (standardized beta [std beta] = -0.60, P = .0001), followed by block density (std beta = -0.15, P = .0002). Implant design showed a weak association (std beta = -0.07, P = .09). In conclusion, fully inserted implants without self-tapping blades have higher initial stability than implants with self-tapping blades. However, the association strength between implant design and initial stability is less relevant than other factors, such as insertion depth and block density. Thus, if bone quality and quantity are optimal, they may compensate for design inadequacy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1563/1548-1336-35.3.130 | DOI Listing |
Front Bioeng Biotechnol
January 2025
Department of Periodontology, School and Hospital of Stomotology, Tianjin Key Laboratory of Oral Soft and Hard Tissues Restoration and Regeneration, Tianjin Medical University, Tianjin, China.
The combination of hydrophilic arginine residues and hydrophobic tryptophan residues is considered to be the first choice for designing short-chain antimicrobial peptides (AMPs) due to their potent antibacterial activity. Based on this, we designed an arginine- and tryptophan-rich short peptide, VR-12. Peri-implantitis is a significant microbial inflammatory disorder characterized by the inflammation of the soft tissues surrounding an implant, which ultimately leads to the progressive resorption of the alveolar bone.
View Article and Find Full Text PDFFront Neurosci
January 2025
The First Affiliated Hospital of Soochow University, Suzhou, China.
Background: Electrically evoked compound action potential (ECAP) can be used to measure the auditory nerve's response to electrical stimulation in cochlear implant (CI) users. In the Nurotron CI system, extracting the ECAP waveform from the stimulus artifact is time-consuming.
Method: We developed a new paradigm ("FastCAP") for use with Nurotron CI devices.
Front Toxicol
January 2025
Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy.
Solid lipid nanoparticles (SLNs) have gained interest as drug delivery carriers due to their efficient cellular internalization and increased therapeutic effect of the loaded drug, with minimal side effects. Although recently several studies have shown the possibility to administer SLNs during pregnancy to vehicle mRNA to the placenta, data about the effect of premating exposure to SLNs on pregnancy outcome are scant. Considering that assumption of drug-delivering nanocarriers in reproductive age may potentially affect women's reproductive health, the aim of the present study was to evaluate whether repeated oral administration of SLNs to female mice prior to mating would influence key pregnancy outcomes.
View Article and Find Full Text PDFHeliyon
January 2025
Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
Purpose: To evaluate the intermediate-term visual and safety outcomes of the small-incision second-generation implantable miniature telescope (SING IMT) in patients with late-stage age-related macular degeneration (AMD) at 6 months post-surgery.
Design: Retrospective cohort study.
Methods: Medical records of patients implanted with the SING IMT at two sites in Italy were reviewed.
Sci Rep
January 2025
Department of Obstetrics and Gynecology, The First Affiliated Hospital of Anhui Medical University, Hefei, 230032, China.
We assessed the safety and efficacy of rhFSH-CTP, a novel long-acting FSH agent, in controlled ovarian hyperstimulation for patients undergoing ART. A multi-center, open-label, randomized, positive-control, non-inferiority clinical trial was conducted. The study consisted of a phase III randomized design, with a 1:1 ratio favoring the rhFSH-CTP group over the control group.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!