Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
To evaluate the accuracy of exercise two-dimensional echocardiography for the recognition of coronary artery disease, 53 patients (46 men and 7 women, age range 35 to 69 years) without either previous myocardial infarction or resting wall motion abnormalities, were studied. According to coronary angiography 26 had normal coronary arteries, 14 had one-vessel, seven had two-vessel, and six had three-vessel disease. After withdrawal of any therapy, all patients underwent a single exercise stress test with a stress table during which cine-loop digitized echocardiography was acquired and 74 MBq of thallium-201 (TI-201) were injected. Echocardiographic images were evaluated at rest and at peak exercise. Three-view planar scintigraphic images were collected immediately after exercise and 4 hours later. For the overall recognition of coronary artery disease, exercise electrocardiography had 77.8% sensitivity and 65.4% specificity; myocardial scintigraphy had 100% sensitivity and 92.3% specificity; and exercise echocardiography had 92.6% sensitivity and 96.2% specificity (both NS versus myocardial scintigraphy). Global accuracy was 71.7% for exercise electrocardiography, 94.3% for stress echocardiography, and 96.2% for myocardial scintigraphy. For the classification of the individual involved coronary arteries, the sensitivity of myocardial scintigraphy was 84.8% and that of exercise echocardiography was 63% (p less than 0.01); the related specificities were 98% and 98.2% respectively (NS). It may be concluded that exercise echocardiography is highly accurate for the recognition of coronary artery disease, whereas it appears less sensitive in the identification of the involved vessels, particularly in patients with multivessel disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0002-8703(91)90278-p | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!