  • The study aimed to determine if temporary postoperative atrial synchronous biventricular pacing could enhance left ventricular function in patients with severely reduced heart function undergoing coronary artery bypass grafting.
  • Results indicated that both biventricular and left ventricular pacing improved certain heart function parameters compared to right ventricular pacing, while diastolic parameters remained mostly unchanged.
  • The conclusion highlights that biventricular and left ventricular pacing methods significantly enhance systolic function after surgery, emphasizing the importance of pacing strategy during postoperative recovery.

Article Abstract

Objective: Patients with severely reduced left ventricular function undergoing coronary artery bypass grafting have increased complication rates. We hypothesized that temporary postoperative atrial synchronous biventricular pacing would improve left ventricular function after cardiopulmonary bypass.

Methods: A left ventricular pressure-volume catheter was placed in 21 patients undergoing coronary artery bypass grafting (ejection fraction 29% +/- 5%). Pressure-volume loops were obtained after weaning from cardiopulmonary bypass with atrial synchronous biventricular, left ventricular, and right ventricular outflow tract pacing and atrial-only stimulation at 90 beats/min.

Results: Steady-state systolic and preload-independent parameters were superior for atrial synchronous biventricular and left ventricular pacing and atrial-only pacing relative to atrial synchronous right ventricular outflow tract pacing (P < .05). Diastolic parameters, excepting maximum negative rate of left ventricular pressure change, were unaffected. No significant differences were observed between atrial synchronous biventricular and left ventricular pacing and atrial-only pacing. Systolic dyssynchrony was significantly lower for atrial synchronous biventricular pacing (21% +/- 5%), atrial synchronous left ventricular pacing (20% +/- 6%), and atrial-only pacing (20% +/- 6%) versus atrial synchronous right ventricular outflow tract pacing (25% +/- 7%, P < .05). Atrioventricular interval during atrial-only stimulation was positively correlated with difference in stroke work between atrial synchronous biventricular pacing and atrial-only pacing (r(2) = 0.78, P > .001).

Conclusion: Postoperative atrial synchronous biventricular and left ventricular pacing and atrial-only stimulation significantly improve systolic function relative to atrial synchronous right ventricular outflow tract pacing. If atrioventricular conduction is prolonged, atrial synchronous biventricular pacing is preferable to atrial-only pacing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2009.02.010DOI Listing

Publication Analysis

Top Keywords

atrial synchronous
48
left ventricular
40
synchronous biventricular
32
biventricular pacing
20
pacing atrial-only
20
atrial-only pacing
20
pacing
17
biventricular left
16
ventricular outflow
16
outflow tract
16

Similar Publications

Even if rarely detected, right atrial (RA) masses represent a diagnostic challenge due to their heterogeneous presentation. Para-physiological RA structures, such as a prominent Eustachian valve, Chiari's network, and lipomatous atrial hypertrophy, may easily be misinterpreted as pathological RA masses, including thrombi, myxomas, and vegetations. Each pathological mass should always be correlated with adequate clinical, anamnestic, and laboratory data.

View Article and Find Full Text PDF

Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.

Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.

View Article and Find Full Text PDF

Artificial Intelligence-Enabled Novel Atrial Fibrillation Diagnosis System Using 3D Pulse Perception Flexible Pressure Sensor Array.

ACS Sens

January 2025

Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China.

Atrial fibrillation (AF) as one of the most common cardiovascular diseases has attracted great attention due to its high disability and mortality rate. Thus, a timely and effective recognition method for AF is of great importance for diagnosing and preventing it. Herein, we proposed a novel intelligent sensing and recognition system for AF which combined Traditional Chinese Medicine (TCM), flexible wearable electronic devices, and artificial intelligence.

View Article and Find Full Text PDF

Background: Imaging both electrical and mechanical cardiac function can better characterize cardiac disease and improve patient care. Currently, there is no noninvasive technique that can simultaneously image both electrical and mechanical function of the whole heart at the point of care. Here, our aim is to demonstrate that high volume-rate echocardiography can simultaneously map cardiac electromechanical activation and end-systolic cardiac strain of the whole heart in a single heartbeat.

View Article and Find Full Text PDF

We herein describe a case of successful atrioventricular synchrony at an 8-week follow-up in a patient who received a leadless pacemaker for recurrent right ventricular lead failures and had a pre-existing atrial transvenous pacemaker. Given the significant hemodynamic improvements, careful initial programming and adjustments during follow-up are needed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!