Thin, large, well-vascularized, and axial-pattern flaps are often desired in the clinical practice of defect reconstruction to maximize esthetic and functional results. Flap prefabrication based on the neovascularization development following vascular pedicle implantation allows surgeons to create such flaps as required. Using different types of implanted vascular pedicles, the aim of the study was to identify the most effective and suitable types of pedicles for clinical use. Five models of implanted vascular pedicles in Chinchilla Bastard rabbits were investigated as follows: model 1, arteriovenous (AV) pedicle with end ligation (minimal blood flow in the implanted vascular pedicle); model 2, AV pedicle with end anastomosis (new shunt formation between vein and artery stump for creating maximal blood flow in the implanted vascular pedicle); model 3, purely isolated arterialized venous loop; model 4, purely isolated arterial loop; model 5, AV pedicle with end anastomosis (similar to model 2) combined with flap expansion. These different types of vascular pedicles were implanted into a random-pattern abdominal skin flap as large as 8 x 15 cm. Neovascularization in the various prefabricated flaps was evaluated macroscopically, scintigraphically, microangiographically, and histologically. A total of 150 prefabricated flaps were investigated and randomly assigned to 5 models with 30 flaps each. Each model contained 5 groups of 6 flaps corresponding to the various retention times of 4, 8, 12, 16, and 20 days after vascular pedicle implantation. Six flaps were also designated to the control group. Neovascularization was best in model 5, followed by comparable results for models 2, 3, and 4, with the worst results found in model 1, especially for the time intervals of 8, 12, and 16 days. Twenty days remains the minimal length of time required for matured neovascularization in all models (P < 0.05). Models 2 and 3 both appear to be particularly promising for clinical application.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0b013e31818a6629DOI Listing

Publication Analysis

Top Keywords

implanted vascular
20
vascular pedicles
16
vascular pedicle
16
model
9
vascular
8
skin flap
8
flap prefabrication
8
pedicle implantation
8
blood flow
8
flow implanted
8

Similar Publications

Chronic fracture-related infection is a complex, costly clinical problem with a wide spectrum of clinical presentations. The goals of treatment are infection control with a healed fracture covered by well-vascularized soft tissue and improvement of patient pain and function. Management is both medical, with culture-targeted antimicrobial agents, and surgical, requiring meticulous irrigation and débridement.

View Article and Find Full Text PDF

Outcomes and Impact of Device Iterations in Mitral Valve Transcatheter Edge-to-Edge Repair: The REPAIR Study.

JACC Cardiovasc Interv

November 2024

Department of Cardiology, Heart Center, Faculty of Medicine, University of Cologne, Cologne, Germany. Electronic address:

Background: The PASCAL P10 system for mitral valve transcatheter edge-to-edge repair has undergone iterations, including introduction of the narrower Ace implant and the Precision delivery system.

Objectives: The study sought to evaluate outcomes and the impact of PASCAL mitral valve transcatheter edge-to-edge repair device iterations.

Methods: The REPAIR (REgistry of PAscal for mltral Regurgitation) study is an investigator-initiated, multicenter registry including consecutive patients with mitral regurgitation (MR) treated from 2019 to 2024.

View Article and Find Full Text PDF

Metastasis represents a stage in which the therapeutic objective changes from curing disease to prolonging survival, as detection typically occurs at advanced stages. Technologies for the early identification of disease would enable treatment at a lower disease burden and heterogeneity. Herein, we investigate the vascular dynamics within a synthetic metastatic niche as a potential marker of disease progression.

View Article and Find Full Text PDF

EGCG-Modified Bioactive Core-Shell Fibers Modulate Oxidative Stress to Synergistically Promote Vascularized Bone Regeneration.

ACS Biomater Sci Eng

January 2025

Research Center for Nano-Biomaterials, Analytical and Testing Center, Sichuan University, Chengdu 610064, PR China.

Oxidative stress induced by reactive oxygen species (ROS) can adversely affect tissue repair, whereas endowing biomaterials with antioxidant activity can improve the in vivo microenvironment, thereby promoting angiogenesis and osteogenesis. Accordingly, this study utilized epigallocatechin-3-gallate (EGCG), a material known for its reducing properties, oxidative self-polymerization capability, and strong binding characteristics, to modify a bioactive core-shell fibrous membrane (10RP-PG). Compared to the 10RP-PG fibrous membrane, the EGCG-modified fibrous membrane (E/10RP-PG) exhibited superior hydrophilicity, excellent cell adhesion, and compatibility.

View Article and Find Full Text PDF

Background: Late gadolinium enhancement (LGE) has been found in patients with autoimmune rheumatic disease (ARD). However, the prognostic implications of some specific LGE patterns in ARD patients remain unclear.

Purpose: To investigate the prevalence and prognostic significance of left ventricular (LV) subendocardium-involved LGE (LGEse) in a cohort of ARD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!