We describe here the fast LC-MS/MS separation of a mixture of neurotransmitters consisting of dopamine, epinephrine, norepinephrine, 3,4-dihydroxybenzylamine (DHBA), salsolinol, serotonin, and gamma-aminobutyric acid (GABA). The new UltiMate 3000 Rapid Separation system (RSLC) was successfully coupled to the 4000 QTRAP mass spectrometer operating in multiple-reaction monitoring (MRM) mode. The separation was attained using a 100 mm length, 2.2 microm particle size Acclaim column at a flow rate of 0.5 mL/min. The column back pressure was 350 bar, while the total run time including column re-equilibration was 5.2 min. The peak resolution was minimally affected by the fast separation. The RSLC-MRM separation was found to have a precision range based on peak area for 50 replicate runs of 2-5% CV for all analytes, and the reproducibility of the retention time for all analytes was found to range from 0-2% CV. The described method represents an almost seven times shorter analysis time of neurotransmitters using LC/MRM which is very useful in screening large quantities of biological samples for various neurotransmitters.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.200900158DOI Listing

Publication Analysis

Top Keywords

multiple-reaction monitoring
8
separation
6
fast liquid
4
liquid chromatography
4
chromatography separation
4
separation multiple-reaction
4
monitoring mass
4
mass spectrometric
4
spectrometric detection
4
neurotransmitters
4

Similar Publications

Objectives: The aim of this study was to establish an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the detection of osimertinib in rat plasma, lung and brain tissues.

Methods: Forty-eight rats were randomly divided into an experimental group (receiving osimertinib at doses of 5, 8, and 10 mg/kg) and a control group. After continuous intragastric administration for 15 days, samples of blood, lung, and brain tissue were collected.

View Article and Find Full Text PDF

Background: Gestational diabetes mellitus (GDM) is defined as a glucose intolerance resulting in hyperglycaemia of variable severity with onset during pregnancy, and is prevalent worldwide. The study of diagnostic markers of GDM in early pregnancy is important for early diagnosis and early intervention of GDM. The aim of this study was to search for biomarkers of GDM in early and mid-pregnancy using a targeted proteomics approach.

View Article and Find Full Text PDF

Background: Caffeic acid phenethyl ester (CAPE) is the main bioactive component of poplar type propolis. We previously reported that treatment with caffeic acid phenethyl ester (CAPE) suppressed the cell proliferation, tumor growth, as well as migration and invasion of prostate cancer (PCa) cells via inhibition of signaling pathways of AKT, c-Myc, Wnt and EGFR. We also demonstrated that combined treatment of CAPE and docetaxel altered the genes involved in glycolysis and tricarboxylic acid (TCA) cycle.

View Article and Find Full Text PDF

Antibody-drug conjugates (ADCs) are a promising drug modality substantially expanding in both the discovery space and clinical development. Assessing the biotransformation of ADCs and is important in understanding their stability and pharmacokinetic properties. We previously reported biotransformation pathways for the anti-B7H4 topoisomerase I inhibitor ADC, AZD8205, puxitatug samrotecan, that underpin its structural stability using an intact protein liquid chromatography-high resolution mass spectrometry (LC-HRMS) approach.

View Article and Find Full Text PDF

Unraveling the in vivo pharmacokinetic behavior of mPEG-NH polymer in rats by UHPLC-MS/MS assay.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

School of Chemical Engineering, Ocean and Life Sciences, Dalian University of Technology, Panjin, Liaoning, 124221, China. Electronic address:

As an important chemical reagent, methoxy polyethylene glycol amine (mPEG-NH) is widely used in biomedical field. Unraveling the pharmacokinetic behavior of mPEG-NH polymers is essential for revealing the toxicity and efficiency of mPEG-NH related drug delivery systems. In this study, a simple analytical assay based on mass spectrometry (MS) was first established and validated for quantification of mPEG-NH in biological matrix.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!