With the development of intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (IMAT), volumetric single arc therapy (RapidArc) and cone beam CT (CBCT) in 3D conformal radiotherapy, a need for new homogeneous treatment tabletops has evolved. Therefore, a new homogenous carbon fibre rotatable treatment tabletop Contesse has been developed. The intension was to create a CT compatible treatment tabletop accommodating all the standard treatment areas without add-on devises or the need to reconfigure the tabletop in everyday practice. At the same time, the absorption was sought to be minimized. Measurements of absorption with an ionization chamber have been performed for the main treatment geometries at normal and oblique angles together with build-up measurements at normal incidence. Absorption and build-up properties were shown to be comparable to those of other treatment tabletops with similar fixation devices. No artefacts from the tabletop are seen on CBCT scans. In order to reveal the absorption characteristics of tabletops, careful measurements at oblique angles including fixation devices on all clinically used tabletops must be performed. The Contesse tabletop is CBCT compatible, has acceptable absorption and is presently being used in the clinic for all patients, including IMRT and kilovoltage CBCT.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/54/14/N04DOI Listing

Publication Analysis

Top Keywords

cone beam
8
arc therapy
8
treatment tabletops
8
treatment tabletop
8
oblique angles
8
fixation devices
8
tabletop cbct
8
absorption
6
tabletop
6
treatment
6

Similar Publications

Comparative Analysis of Gelatin/Polylactic Acid and Commercial PLA Membranes for Guided Bone Regeneration: A Randomized Clinical Trial.

Med Sci Monit

January 2025

Department of Oral Implantology, The Affiliated Stomatology Hospital, Jiangxi Medical College, Nanchang University, Jiangxi Province Key Laboratory of Oral Biomedicine, Jiangxi Province Clinical Research Center for Oral Disease, Nanchang, Jiangxi, China.

BACKGROUND This study included 32 patients with single missing teeth and alveolar bone defects and aimed to compare outcomes from guided bone regeneration with a gelatin/polylactic acid (GT/PLA) barrier membrane and a Guidor® bioresorbable matrix barrier dental membrane. MATERIAL AND METHODS A total of 32 participants were recruited in the clinical study, with single missing teeth and alveolar bone defects, requiring guided bone regeneration (32 missing teeth in total). They were randomly divided into the GT/PLA membrane group (experimental) and Guidor® membrane group (control) by the envelope method (n=16).

View Article and Find Full Text PDF

Purpose: During endovascular revascularization interventions for peripheral arterial disease, the standard modality of X-ray fluoroscopy (XRF) used for image guidance is limited in visualizing distal segments of infrapopliteal vessels. To enhance visualization of arteries, an image registration technique was developed to align pre-acquired computed tomography (CT) angiography images and to create fusion images highlighting arteries of interest.

Methods: X-ray image metadata capturing the position of the X-ray gantry initializes a multiscale iterative optimization process, which uses a local-variance masked normalized cross-correlation loss to rigidly align a digitally reconstructed radiograph (DRR) of the CT dataset with the target X-ray, using the edges of the fibula and tibia as the basis for alignment.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the correlation of the volume and minimum axial area (MAA) measurements between different upper and lower boundaries used for oropharyngeal airway assessment.

Methods: Cone Beam Computed Tomography (CBCT) scans of 49 subjects taken for pre-orthognathic surgical planning were obtained retrospectively from the archives (n = 49; 32 females, 17 males; mean age = 20.9 ± 5.

View Article and Find Full Text PDF

Proximity of maxillary molar palatal roots to adjacent structures for endodontic microsurgery: a cone-beam computed tomography study.

BMC Oral Health

January 2025

Beijing Yakebot Technology Co., Ltd, F-616-West Building, Yonghe Plaza, No. 28 Andingmen Dongdajie, DongCheng District, Beijing, 100007, China.

Background: The surgical complexity associated with the palatal roots of maxillary molars was considerably elevated. Previous studies on the relationships between maxillary molar roots and the maxillary sinus or cortical plates have focused on individual root observation without considering the positional relationship between buccal and palatal roots or analysing the surgical pathway of maxillary molar palatal roots. This study aimed to investigate the relationship between maxillary molar palatal roots and adjacent anatomical structures to provide a reference for performing palatal roots endodontic microsurgery.

View Article and Find Full Text PDF

Purpose: This work aims at investigating, via in-silico evaluations, the noise properties of an innovative scanning geometry in cone-beam CT (CBCT): eCT. This scanning geometry substitutes each of the projections in CBCT with a series of collimated projections acquired over an oscillating scanning trajectory. The analysis focused on the impact of the number of the projections per period (PP) on the noise characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!