Comparison of instruments for investigation of microcirculatory blood flow and red blood cell concentration.

J Biomed Opt

University of Limerick, Tissue Optics and Microcirculation Imaging Facility, Department of Physics, National Technology Park, County Limerick, Ireland.

Published: September 2009

The use of laser Doppler perfusion imaging (LDPI) and laser speckle perfusion imaging (LSPI) is well known in the noninvasive investigation of microcirculatory blood flow. This work compares the two techniques with the recently developed tissue viability (TiVi) imaging system, which is proposed as a useful tool to quantify red blood cell concentration in microcirculation. Three systems are evaluated with common skin tests such as the use of vasodilating and vasoconstricting drugs (methlynicotinate and clobetasol, respectively) and a reactive hyperaemia maneuver (using a sphygmomanometer). The devices investigated are the laser Doppler line scanner (LDLS), the laser speckle perfusion imager (FLPI)-both from Moor Instruments (Axminster, United Kingdom)-and the TiVi imaging system (WheelsBridge AB, Linkoping, Sweden). Both imaging and point scanning by the devices are used to quantify the provoked reactions. Perfusion images of vasodilatation and vasoconstriction are acquired with both LDLS and FLPI, while TiVi images are acquired with the TiVi imager. Time acquisitions of an averaged region of interest are acquired for temporal studies such as the reactive hyperaemia. In contrast to the change in perfusion over time with pressure, the TiVi imager shows a different response due its measurement of blood concentration rather than perfusion. The responses can be explained by physiological understanding. Although the three devices sample different compartments of tissue, and output essentially different variables, comparisons can be seen between the three systems. The LDLS system proves to be suited to measurement of perfusion in deeper vessels, while FLPI and TiVi showed sensitivity to more superficial nutritional supply. LDLS and FLPI are insensitive to the action of the vasoconstrictor, while TiVi shows the clear boundaries of the reaction. Assessment of the resolution, penetration depth, and acquisition rate of each instrument show complimentary features that should be taken into account when choosing a system for a particular clinical measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.3149863DOI Listing

Publication Analysis

Top Keywords

investigation microcirculatory
8
microcirculatory blood
8
blood flow
8
red blood
8
blood cell
8
cell concentration
8
laser doppler
8
perfusion imaging
8
laser speckle
8
speckle perfusion
8

Similar Publications

Background: High levels of catecholamines are cardiotoxic and associated with stress-induced cardiomyopathies. Septic patients are routinely exposed to endogenously released and exogenously administered catecholamines, which may alter cardiac function and perfusion causing ischemia. Early during human septic shock, left ventricular ejection fraction (LVEF) decreases but normalizes in survivors over 7-10 days.

View Article and Find Full Text PDF

Early Microcirculatory Dysfunction on Perfusion CT Is Related to Prognosis After Aneurysmal Subarachnoid Hemorrhage.

Transl Stroke Res

January 2025

Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, No.119 South 4 Ring West Road, Beijing, 100070, Fengtai District, China.

Microcirculatory dysfunction is an important pathophysiology mechanism of early brain injury after aneurysmal subarachnoid hemorrhage (aSAH), which contributes to poor outcomes. The study was performed in Beijing Tiantan Hospital from October 2020 to July 2023. Patients with aSAH who underwent computed tomographic perfusion (CTP) within 24 h after ictus were enrolled prospectively.

View Article and Find Full Text PDF

Oxygen transport across the lifespan of male Sprague Dawley rats.

Biogerontology

January 2025

Song Biotechnologies LLC., Baltimore, MD, 21030, USA.

Human populations are experiencing unprecedented growth and longevity with lingering knowledge gaps of the characteristics, mechanisms, and pathologies of senescence. Invasive measurements and long-term control conditions for longitudinal studies are infeasible, necessitating the need for surrogate animal models. Rats have short lifespans (2-3 years) with translatable cardiovascular systems, and Sprague Dawley microcirculatory preparations are key to studying the oxygen transport mechanisms critical to the loss of skeletal muscle function in aging.

View Article and Find Full Text PDF

Coronary microembolization (CME) is defined as atherosclerotic plaque erosion, spontaneous rupture, or rupture of the plaque while undergoing interventional therapy resulting in the formation of tiny emboli that obstruct the coronary microcirculatory system. For percutaneous coronary intervention, CME is a major complication, with a periprocedural incidence of up to 25%. Recent studies have demonstrated that regulatory cell death (RCD) exerts a profound influence on CME through its modulation of inflammatory responses, oxidative stress, cell death, and angiogenesis.

View Article and Find Full Text PDF

The introduction of wire-free microcirculatory resistance index from functional angiography (angio-IMR) promises swift detection of coronary microvascular dysfunction, however it has not been properly validated. We sought to validate angio-IMR against invasive IMR and PET derived microvascular resistance (MVR). Moreover, we studied if angio-IMR could aid in the detection of ischemia with non-obstructive coronary arteries (INOCA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!