High-compliance endotracheal tube cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage and lead to tracheoesophageal fistula.Tracheostomy tube cuffs seal against the tracheal wall and prevent leakage of air around the tube, assuring that the tidal volume is delivered to the lungs. In the past, high-pressure cuffs were used, but these contributed to tracheal injury and have been replaced by high-volume, low-pressure cuffs. For long-term applications, some newer tubes have low-profile (tight to shaft) cuffs that facilitate the tracheostomy tube changes by eliminating the lip that forms when standard cuffs are deflated.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2700431 | PMC |
http://dx.doi.org/10.4103/1817-1737.37950 | DOI Listing |
J West Afr Coll Surg
August 2024
Department of Anaesthesia, University of Nigeria Teaching Hospital, Ituku-Ozalla, Enugu, Nigeria.
Background: Considerable morbidity is attributable to inappropriate tracheal cuff pressure. An earlier study undertaken in our hospital revealed that a normal cuff pressure of 20-30 cm HO was achieved in only 6% of intubated patients using subjective estimation methods.
Objective: To determine whether a training intervention could improve the accuracy of the subjective estimation method in our tracheal cuff monitoring.
Minerva Anestesiol
September 2024
Department of Anesthesiology and Reanimation, Cukurova University Faculty of Medicine, Adana, Türkiye.
Braz J Anesthesiol
September 2024
Universidade Estadual Paulista (UNESP), Faculdade de Medicina de Botucatu, Departamento de Anestesiologia, São Paulo, SP, Brazil; University of Manitoba, Department of Anesthesiology, Perioperative and Pain Medicine, Winnipeg, MB, Canada.
Background: Postoperative sore throat is one of the main postoperative complaints in patients undergoing tonsillectomy. As the primary outcome, we aimed to determine whether endotracheal tube cuffs filled with alkalinized lidocaine are associated with a lower incidence of postoperative sore throat and anesthesia emergence phenomena in children undergoing tonsillectomy or adenotonsillectomy. We also assessed the potential additional benefits of IV dexamethasone in reducing postoperative laryngotracheal morbidity.
View Article and Find Full Text PDFSci Rep
July 2024
Department of Anesthesiology, First Hospital of Qinhuangdao, N.O. 258, Wenhua Road, Qinhuangdao, Hebei, China.
BJA Open
June 2024
Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Introduction: Leakage of orogastric secretions past the cuff of a tracheal tube is a contributory factor in ventilator-associated pneumonia. Current bench test methods specified in the International Standard for Anaesthetic and Respiratory Equipment (EN ISO 5361:2023) to test cuff leakage involve using a glass or plastic rigid cylinder model of the trachea. There is a need for more realistic models to inform cuff leakage.