Background And Aim: Continuous Subcutaneous Insulin Infusion (CSII) and Multiple Daily insulin Injections (MDI) are both strategies aiming to achieve a tight glycemic and metabolic control. However, the choice between them remains controversial. The aim of the present study was to compare the efficacy of MDI (three or more injections daily) with CSII on glycemic control in patients with Type 1 Diabetes Mellitus and assess satisfaction from treatment in the CSII group.
Material And Methods: Seventeen patients with Type 1 Diabetes Mellitus on CSII (previously on MDI) and 17 patients on MDI, matched for age, gender, BMI and duration of diabetes, were retrospectively studied. Glucosylated Hemoglobin A1c (HbA1c), frequency of hypoglycaemias (assessed as self reported episodes), BMI and total units of insulin per day were evaluated at baseline and after 6 months in both groups. CSII group completed a questionnaire concerning motive for treatment selection, advantages, deficiencies and inconvenience at the end of the study. Satisfaction from treatment was assessed with a scale from 0 to10.
Results: CSII group had more hypoglycaemic episodes at baseline than MDI group (16.2+/-2.8 vs 2.8+/-1.3, p<0,001). HbA1c (8.4+/-0.5 before vs 7.3+/-0.4 after, p<0.05) and total hypoglycaemic episodes per month (16.2+/-2.8 before vs 8.7+/-2.3 after, p<0.05) significantly decreased in CSII group 6 months after baseline. On the contrary, total hypoglycaemic episodes per month were increased in MDI group (2.8+/-1.3 before vs 10.8 +/-2,6 after, p<0.05) in order to maintain HbA1c levels. No significant differences were observed in BMI in both groups. Total insulin demands were reduced in the CSII group (49.4+/-3.3 before vs 39.0+/-4.6 after, p<0.05) and remained unchanged in MDI group. None of the patients discontinued CSII therapy, while overall satisfaction rate in this group was high. The main motive for CSII selection was frequent hypoglycaemic episodes and glucose fluctuations (10/17). The majority of patients expressed their wish for incorporating glucose trend indicator and/or continuous glucose measurement into pump and reducing pump size (15/17). Most commonly stated advantage was improved flexibility, followed by greater freedom and decreased sense of physical restrictions (10/17). Inconvenience mainly derived from alarm malfunction and catheter or needle occlusion and was reported from a minority of patients (4/17).
Conclusion: CSII group reported more hypoglycaemias than MDI group at baseline but 6 months later had significantly less hypoglycaemic events, while on the contrary, MDI group 6 months after baseline had more frequent and more severe hypoglycaemias. Although baseline hypoglycaemias are not equal between the two groups, we can assume that CSII group achieved less hypoglycaemic events along with significant reduction in HbA1c while utilising less insulin units.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2683151 | PMC |
Biomaterials
January 2025
Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, USA; Department of Surgery, Houston Methodist Hospital, Houston, TX, USA; Department of Radiation Oncology, Houston Methodist Hospital, Houston, TX, USA. Electronic address:
Contrasting findings are presented in the literature regarding the influence of foreign body response (FBR) on drug release from implantable drug delivery systems. To this end, here we sought direct evidence of the effect of the fibrotic tissue on subcutaneous drug release from long-acting drug delivery implants. Specifically, we investigated the pharmacokinetic impact of fibrotic encapsulation on a small molecule drug, islatravir (293 Da), and a large protein, IgG (150 kDa), administered via biocompatible implants.
View Article and Find Full Text PDFJ Therm Biol
January 2025
ASSET, INRAE, Petit-Bourg (Guadeloupe), 97170, France.
Estimating animal behaviour during heat stress (HS) is particularly insightful to monitor animal welfare but also to better understand how animals thermoregulate. The present study is a proof of concept combining computer vision to monitor animal behaviour, continuous monitoring of subcutaneous temperature and recording of ambient temperature, with the aim to study the link between behaviour and animal body temperature during HS. A total of 22 pigs were video-monitored from 8:00 to 18.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2025
Heart Center, Department of Cardiology, Amsterdam Cardiovascular Sciences Heart Failure & Arrhythmias, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105, AZ, Amsterdam, the Netherlands.
Background: Little data exists regarding the optimal antithrombotic strategy during S-ICD implantation to prevent pocket hematomas. This study explores the association between perioperative antithrombotic management and the occurrence of pocket hematoma following S-ICD implantation.
Methods: All patients who underwent de novo S-ICD implantation between February 2009 and January 2023 at Amsterdam UMC were included.
Device
October 2024
Division of Gastroenterology, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA 02139, USA.
Naloxone can effectively rescue victims from opioid overdose, but less than 5% survive due to delayed or absent first responder intervention. Current overdose reversal systems face key limitations, including low user adherence, false positive detection, and slow antidote delivery. Here, we describe a subcutaneously implanted robotic first responder to overcome these challenges.
View Article and Find Full Text PDFSurg Laparosc Endosc Percutan Tech
January 2025
Department of Surgery, Division of Gastrointestinal Surgery, University of South Florida Morsani College of Medicine, Tampa, FL.
Background: Peroral endoscopic myotomy (POEM) is a well-established endoscopic treatment for achalasia, utilizing an endoscopic knife for dissection. Recently, new knives with an integrated water-jet (WJ) function have been introduced. This study aims to compare the technical, perioperative, and late postoperative outcomes between WJ knives and conventional (C) knives, which lack the WJ function, through a pairwise meta-analysis of published comparative studies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!