A two-axis scanning catheter was developed for 3D endoscopic imaging with spectral domain optical coherence tomography (SD-OCT). The catheter incorporates a micro-mirror scanner implemented with microelectromechanical systems (MEMS) technology: the micro-mirror is mounted on a two-axis gimbal comprised of folded flexure hinges and is actuated by magnetic field. The scanner can run either statically in both axes or at the resonant frequency (>= 350Hz) for the fast axis. The assembled catheter has an outer diameter of 2.8 mm and a rigid part of 12 mm in length. Its scanning range is +/- 20 in optical angle in both axes with low voltages (1 approximately 3V), resulting in a scannable length of approximately 1 mm at the surface in both axes, even with the small catheter size. The catheter was incorporated with a multi-functional SD-OCT system for 3D endoscopic imaging. Both intensity and polarization-sensitive images could be acquired simultaneously at 18.5K axial scans/s. In vivo 3D images of human fingertips and oral cavity tissue are presented as a demonstration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/oe.15.018130 | DOI Listing |
Int J Radiat Oncol Biol Phys
January 2025
McGill university, Montreal, Qc, Canada.
Purpose: High dose rate (HDR) prostate brachytherapy (BT) procedure requires image-guided needle insertion. Given that general anesthesia is often employed during the procedure, minimizing overall planning time is crucial. In this study, we explore the clinical feasibility and time-saving potential of artificial intelligence (AI)-driven auto-reconstruction of transperineal needles in the context of US-guided prostate BT planning.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy.
This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.
View Article and Find Full Text PDFRadiol Adv
October 2024
Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).
Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.
Nucl Med Commun
February 2025
Department of Radiology, Netherlands Cancer Institute- Antoni van Leeuwenhoekziekenhuis, Amsterdam, The Netherlands.
Background: Small-molecule biomacromolecules target tumor-specific antigens. They are employed as theranostic agents for imaging and treatment. Intravenous small-molecule radioligands exhibit rapid tumor uptake and excretion.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Neurosurgery, Bezirkskrankenhaus Günzburg, University of Ulm, Lindenallee 2, 89312 Günzburg, Germany.
: Post-hemicraniectomy patients often need extended intensive care treatment. While computed tomography (CT) is considered the gold standard for regular imaging, its frequent use could be linked to adverse clinical outcomes. This study aimed to assess bedside transcranial ultrasound (TUS) to capture intracranial anatomical structures and pathologies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!