A complete Fourier Transform Spectropolarimeter in the MWIR is demonstrated. The channeled spectral technique, originally developed by K. Oka, is implemented with the use of two Yttrium Vanadate (YVO(4)) crystal retarders. A basic mathematical model for the system is presented, showing that all the Stokes parameters are directly present in the interferogram. Theoretical results are compared with real data from the system, an improved model is provided to simulate the effects of absorption within the crystal, and a modified calibration technique is introduced to account for this absorption. Lastly, effects due to interferometer instabilities on the reconstructions, including nonuniform sampling and interferograms translations, are investigated and techniques are employed to mitigate them.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.15.012792DOI Listing

Publication Analysis

Top Keywords

fourier transform
8
transform channeled
4
channeled spectropolarimetry
4
spectropolarimetry mwir
4
mwir complete
4
complete fourier
4
transform spectropolarimeter
4
spectropolarimeter mwir
4
mwir demonstrated
4
demonstrated channeled
4

Similar Publications

This study explores the formulation and characterization of poly(vinyl alcohol) (PVA)-based composite hydrogels synthesized through solid-state crosslinking. Comprehensive assessments were conducted on their physicochemical properties, leachables, and immunogenicity. Swelling experiments demonstrated that the incorporation of poly(vinylpyrrolidone) (PVP) enhanced water retention, while chitosan had a minimal effect on swelling behavior.

View Article and Find Full Text PDF

Liquid water still remains an ubiquitous liquid whose molecular organization requires careful investigation. In this work, we present a study of the second harmonic scattering (SHS) intensity for two different scattering angles, namely, the forward and the right angle geometries. This method performed at optical wavelengths is indeed selective toward long correlation lengths.

View Article and Find Full Text PDF

Objective: This study aims to analyze saliva composition in crack users using vibrational spectroscopy.

Material And Methods: A total of 90 participants were meticulously selected and divided into three groups, each comprising 30 individuals. All participants met the criterion of having no observable clinical changes in the oral mucosa.

View Article and Find Full Text PDF

Methylene blue and malachite green dyes adsorption onto /bentonite/tripolyphosphate.

Heliyon

January 2025

Department of Nutrition and Dietetics, Faculty of Health Science, Mardin Artuklu University, Mardin, Turkey.

In the current research mushroom/bentonite clay (RDBNC) as a low-cost bionanosorbent was investigated for adsorption of methylene blue (MB) and malachite green (MG) dye from contaminated water. The bionanosorbent was characterized by Fourier transform infrared (FTIR), X-ray diffraction (XRD), Scanning electron microscopy (FESEM), Thermal Gravimetric Analysis (TGA), and Zeta-potential techniques. Adsorption experiments of RDBNC for MB, MG dyes following Freundlich isotherm and pseudo second order kinetic models.

View Article and Find Full Text PDF

This work reports the synthesis of a copper metal complex with the nonsteroidal anti-inflammatory drug (NSAID) ibuprofen, and 2,2'-dipyridylamine employing microwave-assisted synthesis (MWAS). To the best of authors knowledge, this is the first study reporting a NSAID-based complex achieved through MWAS. The coordination compound was characterised by elemental analysis, Fourier transform infrared spectroscopy, thermogravimetry, and ultraviolet-visible spectrophotometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!