A review of the current evidence for internal fixation versus hemiarthroplasty versus primary total hip arthroplasty for displaced femoral neck fractures was undertaken. At the meta-analysis level no difference in postoperative pain, function, or quality of life can yet be demonstrated. A significant difference in mortality has also not been found, but a trend towards higher mortality after primary arthroplasty is possible. Internal fixation (IF) has less morbidity, but a higher risk of revision and less cost-effectiveness. Independent adjudication for IF technique is rare in studies and bias towards higher revision rates due to technical failure is an issue. Randomized trials comparing IF with arthroplasty remain underpowered in specific subgroups of patients, in which IF revision rates could be acceptable. In hemiarthroplasty the data suggest minimal differences in outcome between the prosthesis types. The cementless Austin-Moore prosthesis is out-dated. Currently a cemented unipolar or bipolar, depending on costs, hemi-arthroplasty is the treatment of choice for an elderly patient with functional limitations before the fracture. The role of modern, uncemented hemiarthroplasty designs are uncertain until more data are published. Total hip arthroplasty (THA) should be considered in any active older patient with a displaced femoral neck fracture. Patients with concomitant osteoarthritis, rheumatoid arthritis, or renal failure do poorly with other treatment options and should be treated with THA. Randomized trials have shown THA to be a cost-effective treatment with lower revision rates than IF. THA may also appear to be superior to hemiarthroplasty in specific subgroups, but larger trials are needed to confirm this observation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0b013e318176147d | DOI Listing |
Sci Rep
January 2025
Department of Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.
View Article and Find Full Text PDFBackground: There has been an increase in both primary anatomic (aTSA) and reverse total shoulder arthroplasty (rTSA) over the last decade, with rates peaking for patients aged 75 years and older. Despite aTSA being the mainstay of treatment for patients with glenohumeral arthritis in the absence of rotator cuff insufficiency, there has been an upward trend of rTSA utilization in the elderly due to concerns about rotator cuff integrity, regardless of deformity. The purpose of this study is to evaluate outcomes including pain, function, range of motion, satisfaction, and complications in patients 80 years or older following primary anatomic and reverse total shoulder arthroplasty for osteoarthritis without full thickness rotator cuff tears.
View Article and Find Full Text PDFInjury
January 2025
Department of Surgery, The Trauma and Orthopaedic Research Unit, The Canberra Hospital, Garran, Australian Capital Territory, Australia.
Background: Unstable posterior pelvic-ring fractures are rare and difficult to manage. There are many injury patterns, they are associated with high morbidity and mortality, and optimal surgical management remains contentions. This study aims to compare outcomes and complications for different surgical management of these injuries.
View Article and Find Full Text PDFAm J Case Rep
January 2025
Department of Orthopedic Surgery, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
BACKGROUND The management of unstable atlas fractures remains a subject of ongoing debate and controversy. The conservative surgical treatment commonly involves fusion, resulting in severe loss of cervical spine mobility, and a large incisions and extensive tissue dissection are required. We aim to introduce a novel concept and surgical approach for treating atlas fracture, one that involves minimizing trauma while maintaining mobility of the upper cervical spine without resorting to fusion.
View Article and Find Full Text PDFJ Clin Med
January 2025
Shoulder and Elbow Surgery, Schulthess Clinic Zürich, 8008 Zürich, Switzerland.
: Classical reverse shoulder arthroplasty (RSA) with a high neck-shaft angle (NSA) of 155° has shown satisfactory outcomes. However, newer RSA designs aim to improve results by modifying the stem design. This study evaluates the 5-year outcomes of a stem design featuring a rectangular metadiaphyseal fixation and a 135° NSA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!