A 10Gb/s NRZ burst-mode optical receiver suitable for receiving asynchronous bursts with power variations of up to 7 dB is presented. The digital burst mode receiver is based on a standard AC-coupled photodiode followed by asynchronous analogue to digital conversion at 20 GS/s. Symbol timing, amplitude and baseline wander corrections are implemented in digital signal processing without the need for additional linecoding, such as 8B10B, and special AC-coupling schemes. It is assumed that G.709 framing together with enhanced FEC is used therefore the receiver is characterized using a pre eFEC BER of 10(-3) at an input OSNR of 10 dB. We show that the addition of an electronically controlled SOA for optical power equalization before the receiver extends the burst-to-burst dynamic range from the 7 dB provided by the digital receiver alone to 16.5 dB. The large dynamic range, low overhead, and burst length versatility make this type of receiver ideal for applications in both synchronous and asynchronous dynamic network architectures with burst timescales ranging from nanoseconds through to continuous data.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.15.009520DOI Listing

Publication Analysis

Top Keywords

dynamic range
8
receiver
7
digital
5
optically equalized
4
equalized gb/s
4
gb/s nrz
4
nrz digital
4
digital burstmode
4
burstmode receiver
4
dynamic
4

Similar Publications

The Acinetobacter baumannii is a member of the "ESKAPE" bacteria responsible for many serious multidrug-resistant (MDR) illnesses. This bacteria swiftly adapts to environmental cues leading to the emergence of multidrug-resistant variants, particularly in hospital/medical settings. In this work, we have demonstrated the outer membrane protein 33-36 (Omp33-36) porin as a potential therapeutic target in A.

View Article and Find Full Text PDF

Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.

View Article and Find Full Text PDF

Roaming reactions involving a neutral fragment of a molecule that transiently wanders around another fragment before forming a new bond are intriguing and peculiar pathways for molecular rearrangement. Such reactions can occur for example upon double ionization of small organic molecules, and have recently sparked much scientific interest. We have studied the dynamics of the [Formula: see text]-roaming reaction leading to the formation of [Formula: see text] after two-photon double ionization of ethanol and 2-aminoethanol, using an XUV-UV pump-probe scheme.

View Article and Find Full Text PDF

Phase transitions in the mantle control its internal dynamics and structure. The post-spinel transition marks the upper-lower mantle boundary, where ringwoodite dissociates into bridgmanite plus ferropericlase, and its Clapeyron slope regulates mantle flow across it. This interaction has previously been assumed to have no lateral spatial variations, based on the assumption of a linear post-spinel boundary in pressure and temperature.

View Article and Find Full Text PDF

High-affinity VNARs targeting human hemoglobin: Screening, stability and binding analysis.

Int J Biol Macromol

January 2025

College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China. Electronic address:

Hemoglobin, composed of α- and β-chains, is essential for oxygen transport and is key in diagnosing and treating gastrointestinal and blood disorders. It also aids in detecting blood contamination and estimating transfusion volumes. Immunological methods, based on antigen-antibody interactions, are distinguished by their high sensitivity and accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!