Most Mueller matrix imaging polarimeters implement sequential acquisition of at least 16 raw images of the same object with different incident and detected light polarizations. When this technique is implemented in vivo, the unavoidable motions of the subject may shift and distort the raw images to an extent such that the final Mueller images cannot be extracted. We describe a registration algorithm which solves this problem for the typical conditions of in vivo imaging, e.g. with spatially inhomogeneous medium to strong depolarization. The algorithm, based on the so called "optical flow," is validated experimentally by comparing the Mueller images of a pig skin sample taken in static and in dynamic conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.15.007393DOI Listing

Publication Analysis

Top Keywords

mueller matrix
8
matrix imaging
8
raw images
8
mueller images
8
registration scheme
4
scheme suitable
4
mueller
4
suitable mueller
4
imaging biomedical
4
biomedical applications
4

Similar Publications

Purpose: Diffusion magnetic resonance imaging (dMRI) quantitatively estimates brain microstructure, diffusion tractography being one clinically utilized framework. To advance such dMRI approaches, direct quantitative comparisons between microscale anisotropy and orientation are imperative. Complete backscattering Mueller matrix polarized light imaging (PLI) enables the imaging of thin and thick tissue specimens to acquire numerous optical metrics not possible through conventional transmission PLI methods.

View Article and Find Full Text PDF

The nanoscale chiral arrangement in a bicomponent organic material system comprising donor and acceptor small molecules is shown to depend on the thickness of a film that is responsive to chiral light in an optoelectronic device. In this bulk heterojunction, a previously unreported chiral bis(diketopyrrolopyrrole) derivative was combined with an achiral non-fullerene acceptor. The optical activity of the chiral compound is dramatically different in the pure material and the composite, showing how the electron acceptor influences the donor's arrangement compared with the pure molecule.

View Article and Find Full Text PDF

Polarimetry terahertz imaging of human breast cancer surgical specimens.

J Med Imaging (Bellingham)

November 2024

University of Arkansas, Department of Electrical Engineering and Computer Science, Fayetteville, Arkansas, United States.

Article Synopsis
  • The study focuses on using terahertz (THz) polarimetry imaging to enhance contrast between cancerous tissue and healthy tissue in human breast cancer specimens.
  • It utilizes multiple polarizations to capture how cancerous cells interact differently with THz electric fields compared to healthy cells, aiming for better image clarity.
  • Results show that cross-polarization signals are dependent on tissue orientation, revealing patterns that help differentiate between various tissue types, indicating THz polarimetry's potential for improved imaging in tumor analysis.
View Article and Find Full Text PDF

Achilles tendon injuries, as a widely existing disease, have attracted a lot of research interest. Mueller matrix polarimetry, as a novel label-free quantitative imaging method, has been widely used in various applications of lesion identification and pathological diagnosis. However, focusing on the recovery process of Achilles tendon injuries, current optical imaging methods have not yet achieved the label-free precise identification and quantitative evaluation.

View Article and Find Full Text PDF

Aluminium nanoparticle-based ultra-wideband high-performance polarizer.

Heliyon

October 2024

Department of Electrical and Electronic Engineering, Bangladesh University of Engineering and Technology, Dhaka, 1205, Bangladesh.

Article Synopsis
  • - The study focuses on the development of high-quality nanoscale wideband polarizers using aluminum (Al) dimer nanostructures, which have shown superior performance compared to traditional wire-grid designs, especially in the near-infrared (NIR) and terahertz (THz) ranges.
  • - A novel nanoparticle polarizer design features semi-immersed Al nano-dimers on a calcium fluoride (CaF) substrate, achieving an impressive extinction ratio exceeding 55 dB across a 0.2 to 9 THz range, with peak values of 60 dB in the THz region.
  • - The research evaluates key performance parameters including insertion loss (about 1 dB) and overall
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?