The current study evaluated in-vitro microleakage of indirect composite inlays fixed with flowable composite and resinous cement and cured by LEDs and QTH units, thus modifying the internal conditioning of the inlays. Thirty-two non-carious teeth were selected and 64 cavity preparations were performed in both enamel and cementum. These teeth were divided into four groups: I--Elipar FreeLight appliance and Filtek Flowable composite; II--Ultralux appliance and Filtek Flowable composite; III--Elipar FreeLight appliance and RelyX cement and IV--Ultralux appliance and RelyX cement. The inlays were internally sandblasted with aluminum oxide, etched with 37% phosphoric acid, washed and silanized. The dental etching was carried out with 37% phosphoric acid for 15 seconds in dentin and 30 seconds in enamel. After being washed and dried, Single Bond dentinal adhesive was then applied, and the inlays were fixed with their respective luting agents, cured in close contact with their surfaces for 60 seconds, thermocycled and immersed in 0.5% basic fuchsine solution. The teeth were then washed and sectioned through the center of the restoration in order for the microleakage readings to be performed using the Image Tool Software. Then, ANOVA and Tukey's statistical tests were applied. In enamel, there was no significant difference for both groups with regard to microleakage; in cementum, the significant difference was 5% (p > 0.005). In agreement with the results, the inlays can be fixed with RelyX and Filtek Flowable resins.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2341/08-83 | DOI Listing |
Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.
Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.
J Adv Prosthodont
December 2024
Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.
Purpose: This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.
Materials And Methods: A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner.
BMC Oral Health
January 2025
Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Background: Increasing demand for durable and aesthetically pleasing dental restorations, including laminates, inlays, onlays, and crowns, has led to advancements in all-ceramic systems, particularly with the development of advanced lithium disilicate materials. However, limited data on the fit accuracy and fracture resistance of these materials restricts their wider application in clinical restorative practices.
Aim Of The Study: This in vitro study aims to compare the marginal and internal fit, assess the fracture resistance, and evaluate the failure modes of crowns fabricated from advanced and conventional lithium disilicate materials.
Int Braz J Urol
December 2024
Serviço de Urologia - Hospital Federal da Lagoa, Rio de Janeiro, RJ, Brasil.
Clin Oral Investig
December 2024
Department of Prosthetic Dentistry, Medical Faculty, Heidelberg University, Heidelberg, Germany.
Objectives: To prospectively evaluate the wear of posterior zirconia resin-bonded fixed partial dentures (RBFPDs) with polished occlusal surfaces and their natural enamel antagonists compared to contralateral controls in an enamel-enamel contact over 5 years.
Materials And Methods: In six patients with either an inlay- or wing-retained RBFPD made of monolithic 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), wear was evaluated indirectly using baseline and annual polyvinyl siloxane impressions. Resulting gypsum models were digitized and aligned by unchanged surface areas.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!