Methods of cooling: practical aspects of therapeutic temperature management.

Crit Care Med

Division of Pulmonary and Critical Care Medicine, Maine Medical Center, Tufts University School of Medicine, Portland, ME, USA.

Published: July 2009

Objectives: To review traditional and newer means of inducing, maintaining, and withdrawing therapeutic hypothermia and normothermia. To suggest treatment algorithms for temperature modulation and review neuromonitoring options.

Design: A review of current literature describing methods of performing therapeutic temperature management and neuromonitoring during the cooling, maintenance, and decooling periods. Algorithms for performing therapeutic temperature management are suggested.

Results: Temperature management can be safely and effectively performed using traditional or newer modalities. Although traditional means of cooling are feasible and efficacious, modern devices utilizing feedback loops to maintain steady body temperature and prevent overcooling have advantages in ease of application, patient safety, maintenance of target temperature, and control of decooling. Neuromonitoring options should be adapted to an individual patient and situation.

Conclusions: Intensivists should be familiar with techniques to induce, maintain, and withdraw therapeutic temperature management, and select the most appropriate method for a given patient and situation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/CCM.0b013e3181aa5badDOI Listing

Publication Analysis

Top Keywords

temperature management
20
therapeutic temperature
16
temperature
8
traditional newer
8
performing therapeutic
8
therapeutic
5
management
5
methods cooling
4
cooling practical
4
practical aspects
4

Similar Publications

Accurate operando measurement of AlGaN/GaN HEMTs channel temperature and optimization of thermal design.

Nanotechnology

January 2025

Electronic Sci.&Eng., Xi'an Jiaotong University, 28 Xianning West Road,Beilin District, Xi 'an, Shaanxi Province, China, Xi'an, 710049, CHINA.

The accurate estimation of the temperature distribution of the GaN based power devices and optimization of the device structure is of great significance to possibly solve the self-heating problem, which hinders the further enhancement of the device performances. We present here the operando temperature measurement with high spatial resolution using Raman spectroscopy of AlGaN/GaN high electron mobility transistors (HEMTs) with different device structures and explore the optimization of the device thermal design accordingly. The lateral and depth temperature distributions of the single-finger HEMT were characterized.

View Article and Find Full Text PDF

The citrus pest Cacopsylla citrisuga (Yang & Li), a vector for Citrus Huanglongbing (HLB), exhibits distinct sensitivity to temperature variations. This study utilized an age-stage, 2-sex life table to evaluate the development and reproduction of C. citrisuga across 5 temperatures (17, 20, 25, 28, and 31 °C).

View Article and Find Full Text PDF

Effects of cold-water immersion on health and wellbeing: A systematic review and meta-analysis.

PLoS One

January 2025

Alliance for Research in Exercise Nutrition and Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, Australia.

Background: Cold-water immersion (CWI) has gained popularity as a health and wellbeing intervention among the general population.

Objective: This systematic review and meta-analysis aimed to evaluate the psychological, cognitive, and physiological effects of CWI in healthy adults.

Methods: Electronic databases were searched for randomized trials involving healthy adults aged ≥ 18 years undergoing acute or long-term CWI exposure via cold shower, ice bath, or plunge with water temperature ≤15°C for at least 30 seconds.

View Article and Find Full Text PDF

Solar-driven desalination technology is currently an important way to obtain freshwater resources. Significantly, porous materials are used as substrate materials of interface solar evaporator, and their specific impact of water transport property and thermal management during evaporation is worth exploring. In this paper, poly(vinyl alcohol) (PVA) sponges were prepared by a chemical foaming method, adjusted the PVA polymerization degree, and formaldehyde-hydroxyl ratio to regulate the pore size, and polypyrrole (PPy) was grown in situ on the surface skeleton of PVA sponge to construct a new interfacial solar evaporator (PPy/PVA) with different pore structures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!