Diagnostic reference levels for the most frequent radiological examinations carried out in Brazil.

Rev Panam Salud Publica

Instituto de Física Gleb Wataghin (IFGW), Universidade Estadual de Campinas-UNICAMP, Departamento de Física Aplicada, Cidade Universitária Zeferino Vaz, Campinas, Brazil.

Published: February 2009

Objectives: A large-scale survey of doses to patients undergoing the most frequent radiological examinations was carried out in health services in São Paulo (347 radiological examinations per 1 000 inhabitants), the most populous Brazilian state.

Methods: A postal dosimetric kit with thermoluminescence dosimeters was used to evaluate the entrance surface dose (ESD) to patients. A stratified sampling technique applied to the national health database furnished important data on the distribution of equipment and the annual number of examinations. Chest, head (skull and sinus), and spine (cervical, thoracic, and lumbar) examinations were included in the trial. A total of 83 rooms and 868 patients were included, and 1 415 values of ESD were measured.

Results: The data show large coefficients of variation in tube charge, giving rise to large variations in ESD values. Also, a series of high ESD values associated with unnecessary localizing fluoroscopy were detected. Diagnostic reference levels were determined, based on the 75th percentile (third quartile) of the ESD distributions. For adult patients, the diagnostic reference levels achieved are very similar to those obtained in international surveys. However, the situation is different for pediatric patients: the ESD values found in this survey are twice as large as the international recommendations for chest radiographs of children.

Conclusions: Despite the reduced number of ESD values and rooms for the pediatric patient group, it is recommended that practices in chest examinations be revised and that specific national reference doses and image quality be established after a broader survey is carried out.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s1020-49892009000200001DOI Listing

Publication Analysis

Top Keywords

esd values
16
diagnostic reference
12
reference levels
12
radiological examinations
12
frequent radiological
8
examinations carried
8
esd
7
examinations
6
patients
5
values
5

Similar Publications

An electrochromic supercapacitor device (ESD) is an advanced energy storage device that combines the energy storage capability of a supercapacitor with the optical modulation properties of electrochromic materials. The electrode materials used to construct an ESD need to have both rich color variations and energy storage properties. Recent advances in ESDs have focused on the preparation of novel electrochromic supercapacitor electrode materials and improving their energy storage capacity, cycling stability, and electrochromic performance.

View Article and Find Full Text PDF

Background: Submucosal tunneling endoscopic resection (STER) is considered an effective, safe and minimally invasive treatment for esophageal subepithelial lesions (SELs) with maximal dilameter less than 3.0 cm, yet its efficacy for lesions over 3.0 cm remains unclear.

View Article and Find Full Text PDF

A case of Gastric cystic polyp mimicking early gastric cancer.

J Gastrointestin Liver Dis

December 2024

Department of Gastroenterology and Hepatology, West China Tianfu Hospital, Sichuan University, Chengdu, Sichuan Province; Department of Gastroenterology and Hepatology, West China Hospital of Sichuan University, Chengdu, Sichuan Province, China.

In this study, we present a case of a 51-year-old man with a gastric lesion initially suspected to be early gastric cancer but was ultimately diagnosed as a Gastric cystic polyp (GCP). The patient underwent diagnostic endoscopic submucosal dissection (ESD) based on the lesion's appearance and characteristics. Detailed pathological and immunohistochemical analysis confirmed the diagnosis of GCP.

View Article and Find Full Text PDF

Objectives: Colorectal endoscopic submucosal dissection (ESD) for large tumors is spreading worldwide. Gastric cancer (GC) sometimes occurs after colorectal ESD. However, its status including frequency and risk factors have not been examined well.

View Article and Find Full Text PDF

The depth of invasion plays a critical role in predicting the prognosis of early esophageal cancer, but the reasons behind invasion and the changes occurring in invasive areas are still not well understood. This study aimed to explore the morphological differences between invasive and non-invasive areas in early esophageal cancer specimens that have undergone endoscopic submucosal dissection (ESD), using artificial intelligence (AI) to shed light on the underlying mechanisms. In this study, data from 75 patients with esophageal squamous cell carcinoma (ESCC) were analyzed and endoscopic assessments were conducted to determine submucosal (SM) invasion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!