We present spectral interferometric four-wave mixing (FWM) microscopy with a nearly shot-noise limited sensitivity and with the capability of separating FWM signals from fluorescence signals. We analyze the requirements for obtaining the shot-noise limited sensitivity and experimentally achieve the sensitivity that is only 4-dB lower than the shot-noise limit. Moreover, we show that only FWM signals can be extracted through the Fourier filtering even when the FWM spectrum is overlapped and overwhelmed by the fluorescence spectrum. We demonstrate simultaneous acquisition of FWM and two-photon excited fluorescence images of fluorescent monodispersed polystyrene microspheres.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.14.011204DOI Listing

Publication Analysis

Top Keywords

spectral interferometric
8
interferometric four-wave
8
four-wave mixing
8
two-photon excited
8
excited fluorescence
8
shot-noise limited
8
limited sensitivity
8
fwm signals
8
fwm
5
highly sensitive
4

Similar Publications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored.

View Article and Find Full Text PDF

Simultaneous visualization of membrane fluidity and morphology defines adhesion signatures of cancer cells.

Proc Natl Acad Sci U S A

December 2024

Department of Applied Physics, Graduate School of Engineering, Osaka University, Suita 565-0871, Japan.

Article Synopsis
  • - We created a new optical microscope that can simultaneously image both the fluidity and structure of cell membranes to understand cell adhesion better.
  • - In tests, we observed how a giant unilamellar vesicle interacts with a glass surface, revealing areas of membrane fluidity and corresponding adhesion sites in both cancerous and non-cancerous cells.
  • - By manipulating cholesterol and unsaturated lipids, we identified distinct adhesion signatures in cancer cells, suggesting that our microscope could help study membrane properties in various cell types beyond just cancer.
View Article and Find Full Text PDF

Semiconducting halide perovskite nanoparticles support Mie-type resonances that confine light on the nanoscale in localized modes with well-defined spatial field profiles yet unknown near-field dynamics. We introduce an interferometric scattering-type near-field microscopy technique to probe the local electric field dynamics at the surface of a single MAPbI nanoparticle. The amplitude and phase of the coherent light scattering from such modes are probed in a broad spectral range and with high spatial resolution.

View Article and Find Full Text PDF

This study presents the development of stannous chloride (SnCl)-modified glass substrates for biomolecule immobilization and their application in fabricating sensor chips for label-free interferometric biosensors. The glass modification process was optimized, identifying a 5% SnCl concentration, a 45 min reaction time, and a 150 °C drying temperature as conditions for efficient protein immobilization. Based on the SnCl-modified glass substrates and label-free spectral-phase interferometry, a biosensor was developed for the detection of aflatoxin B1 (AFB1)-a highly toxic and carcinogenic contaminant in agricultural products.

View Article and Find Full Text PDF
Article Synopsis
  • The paper presents a method to reduce noise in fiber-optic sensing systems using spectral subtraction and statistical noise estimation, aimed at improving signal clarity before demodulation.
  • By processing interference signals with averaged noise spectrum estimates from different windowed signals, the technique effectively minimizes noise aliasing.
  • Experimental results show a significant average noise floor reduction of 25 dB across the 0-5 kHz range and up to 30 dB at 50 kHz, all without needing extra optical devices, making the system simpler and more cost-effective.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!