Loa loa is a filarial nematode that infects humans. The adults live in subcutaneous tissues and produce microfilariae that live for several weeks in the blood circulation in order to be transmitted to another person via blood meals of a dipterian vector. As microfilariae live in continuous contact with plasma, it is obvious that they evade the complement system. We studied markers of complement activation and signs of complement regulation on Loa loa microfilariae in vivo. The microfilariae were isolated from anticoagulated blood samples of a Loa loa-infected Caucasian patient. C1q and some mannose-binding lectin but only a limited amount of C3b or C4b fragments and practically no C5 or C5b-9 were present on the microfilariae. The covalently microfilaria-bound C3 and C4 depositions were mainly inactive iC3b, C3c, and iC4b fragments indicating that microfilariae had regulated complement activation in vivo. Also, in vitro deposition of C3b onto the microfilariae upon serum exposure was limited. The patient-isolated microfilariae were found to carry the host complement regulators factor H and C4b-binding protein on the outermost layer, so called sheath. The microfilaria-bound factor H was functionally active. Binding of the complement regulators to the microfilariae was confirmed in vitro using (125)I-labeled factor H and C4b-binding protein. In conclusion, our study shows that Loa loa microfilariae block complement activation and acquire the host complement regulators factor H and C4b-binding protein in blood circulation. This is the first time that binding of complement regulators onto nonviral pathogens has been demonstrated to occur in humans in vivo.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2738024 | PMC |
http://dx.doi.org/10.1128/IAI.01583-08 | DOI Listing |
J Rehabil Med
January 2025
University of Florence, Department of Experimental and Clinical Medicine, Firenze, Italy; IRCCS Fondazione Don Carlo Gnocchi, Firenze, Italy.
Background: The Motricity Index (MI) is a commonly used method of measuring muscle strength in post-stroke hemiparesis. This study aimed to produce the MI Italian version (MI-IT) and assess its reliability in subjects with stroke.
Methods: Phase-1: stepwise approach to MI-IT production and pilot-testing with 10 health professionals to ensure clarity of each item and instructions for administration and scoring.
BMC Musculoskelet Disord
January 2025
Department of Health Sciences, University of Eastern Piedmont, 28100, Novara, Italy.
Introduction: Hand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar® hydraulic dynamometer (JD), the gold standard.
Methods: Fifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD.
PLoS One
January 2025
Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea.
Background: Monitoring core temperature is important for patients under anesthesia. Esophageal and pulmonary artery blood temperatures can be used for measuring core temperature during general anesthesia. However, these methods pose challenges, especially when the placement of an esophageal thermometer and pulmonary artery catheter (PAC) is either impractical or not the preferred approach.
View Article and Find Full Text PDFJ Neurol Phys Ther
December 2024
Department of Physical Therapy, Motor Control Laboratory (LADECOM), Centre of Healthy and Sport Sciences, University of Santa Catarina State, Florianópolis, Santa Catarina, Brazil.
Background And Purpose: Telerehabilitation represents an alternative for individuals who have difficulty accessing services to receive care. Therefore, telerehabilitation measures must be studied for their reliability and validity. This study evaluated the validity and reliability of the videoconference-based Berg Balance Scale assessment in stroke survivors.
View Article and Find Full Text PDFJ Clin Monit Comput
December 2024
Department of Anesthesia and Intensive Care, "Policlinico San Marco" University Hospital, Catania, Italy.
Echocardiography is crucial for evaluating patients at risk of clinical deterioration. Left ventricular ejection fraction (LVEF) and velocity time integral (VTI) aid in diagnosing shock, but bedside calculations can be time-consuming and prone to variability. Artificial intelligence technology shows promise in providing assistance to clinicians performing point-of-care echocardiography.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!