Background: To evaluate the safety, reproducibility and pitfalls of an aortic valve re-implantation (AVRei) technique.
Methods: From June 2005 to December 2008, 30 patients underwent aortic valve-sparing re-implantation with Gelweave Valsalva prosthesis. Mean age was 66 +/- 7 years (range 47-81). Mean aortic root diameter was 49 +/- 6 mm (range 37-70) and 12 patients had an aortic insufficiency more than 2+. All the patients were elective, except three who underwent surgery for type A aortic dissection. Two patients had Marfan syndrome and one had a bicuspid aortic valve. Isolated aortic root replacement was performed in 26 patients, whereas hemiarch extension was required in four. All the survivors underwent serial echocardiographic assessment for functional results and multi-detector computed tomography (MDCT) for aortic root morphology evaluation.
Results: There was one early death and one re-exploration for bleeding. Two patients suffered from a perioperative stroke and four required a pacemaker implantation because of a complete atrio-ventricular block. Mean follow-up was 12 +/- 10 months (range 1-42) with no late deaths, whereas freedom from reoperation was 100% and freedom from aortic insufficiency 2+ or more was 96.5%. MDCT aortic root reconstruction showed a pseudo-normalization of the neo-sinuses of Valsalva mimicking the human normal aortic root morphology.
Conclusion: AVRei with Valsalva conduit is a well-tolerated procedure both in elective and emergency situations. In well-selected patients, good functional and clinical results can be achieved, regardless of the cause of the aortic root disease. Application of simple surgical manoeuvres allows durable clinical efficacy to be obtained without the risk of major complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2459/JCM.0b013e32832e0acc | DOI Listing |
Sci Rep
January 2025
University of Ulsan, 93 Daehak-ro, Nam-gu, Ulsan, 680-749, Republic of Korea.
This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Division of Vascular Surgery, University of Maryland, Baltimore, Maryland.
Background: Thoracic Endovascular Aortic Repair (TEVAR) reduced mortality for blunt aortic injury (BAI) from 30-50% to < 10%; however, penetrating traumatic aortic injury (PAI) remains highly lethal (>40% mortality). This study's goal is to determine outcomes of TEVAR for PAI.
Methods: Patients undergoing TEVAR for traumatic aortic injuries were identified from the Vascular Quality Initiative database from 2011-2022.
J Clin Med
January 2025
Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany.
: In the presence of porcelain aorta (PA), transcatheter aortic valve replacement (TAVR) has become a class I therapeutic indication for the treatment of severe aortic valve stenosis. To date, few studies have analyzed the clinical outcomes of TAVR in PA patients. We aim to analyze the calcification patterns of the thoracic aorta in PA patients and to evaluate their clinical implications for TAVR procedures.
View Article and Find Full Text PDF: EnBloc resections of bone tumors of the spine are very demanding as the target to achieve a tumor-free margin specimen (sometimes impossible due to the extracompartimental tumor extension) is sometimes conflicting with the integrity of neurological functions and spine stability. : The surgical treatment of a huge multi-level chordoma of the thoracic spine with unusual extension is reported. Anteriorly, the tumor widely invaded the mediastinum and displaced the aorta; on the left side, it expanded in the subpleuric region; posteriorly, it was uncommonly distant 13 mm from the posterior wall.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Cardiovascular Surgery, Houston Methodist Hospital, 6550 Fannin St, Houston, TX 77030, USA.
: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!