Color Doppler imaging of cardiac catheters using vibrating motors.

Ultrason Imaging

Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.

Published: October 2008

A miniature motor rotating at 11,000 rpm was attached onto the proximal end of cardiac electrophysiological (EP) catheters in order to produce vibrations at the tip that were then visualized by color Doppler on ultrasound scanners. The catheter tip was imaged within a vascular graft submerged in a water tank using the Volumetrics Medical Imaging 3D scanner, the Siemens Sonoline Antares 2D scanner and the Philips ie33 3D ultrasound scanner with TEE probe. The vibrating catheter tip was visualized in each case, although results varied with the color Doppler properties of the individual scanner.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2804844PMC
http://dx.doi.org/10.1177/016173460803000408DOI Listing

Publication Analysis

Top Keywords

color doppler
12
doppler imaging
4
imaging cardiac
4
cardiac catheters
4
catheters vibrating
4
vibrating motors
4
motors miniature
4
miniature motor
4
motor rotating
4
rotating 11000
4

Similar Publications

Optimizing the life of vascular access during follow-up.

J Cardiovasc Surg (Torino)

February 2025

Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.

Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.

View Article and Find Full Text PDF

Aim: The current investigation aimed to evaluate the accuracy of ultrasonography and color Doppler performed in the diagnosis of intraosseous jaw lesions.

Materials And Methods: A total of 30 patients with intraosseous jaw lesions between the ages of 12 and 60 were selected for the present study. For every jaw lesion, a preliminary diagnosis was done using preoperative conventional radiographs.

View Article and Find Full Text PDF

Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt.

Case Summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post-endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage.

View Article and Find Full Text PDF

Aims: Studies specifically examining the sonographic features of juvenile fibroadenoma in the pediatric population have not been documented. We aimed to analyze sonograms of juvenile fibroadenoma in children.

Subjects And Methods: Patients aged ≤ 18 years who underwent breast ultrasound examinations at our department and had pathologically proven juvenile fibroadenoma from September 2002 to January 2022 were included in this study.

View Article and Find Full Text PDF

Monitoring of perioperative tissue perfusion and impact on patient outcomes.

J Cardiothorac Surg

January 2025

Department of Anesthesiology, Zhongda hospital, Southeast University, No. 87 Dingjiaqiao, Nanjing City, 210009, Jiangsu Province, China.

Monitoring perioperative tissue perfusion is crucial in clinical anesthesia to protect organs and ensure patient safety. Indicators like hemodynamic parameters, tissue metabolism, and microcirculation markers are used for assessment. Studies show intraoperative hypotension negatively impacts outcomes, though blood pressure alone may not reflect tissue perfusion accurately.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!